DNA accumulation on ventilation system filters in university buildings in Singapore
نویسندگان
چکیده
INTRODUCTION Biological particles deposit on air handling system filters as they process air. This study reports and interprets abundance and diversity information regarding biomass accumulation on ordinarily used filters acquired from several locations in a university environment. METHODS DNA-based analysis was applied both to quantify (via DNA fluorometry and qPCR) and to characterize (via high-throughput sequencing) the microbial material on filters, which mainly processed recirculated indoor air. Results were interpreted in relation to building occupancy and ventilation system operational parameters. RESULTS Based on accumulated biomass, average DNA concentrations per AHU filter surface area across nine indoor locations after twelve weeks of filter use were in the respective ranges 1.1 to 41 ng per cm2 for total DNA, 0.02 to 3.3 ng per cm2 for bacterial DNA and 0.2 to 2.0 ng DNA per cm2 for fungal DNA. The most abundant genera detected on the AHU filter samples were Clostridium, Streptophyta, Bacillus, Acinetobacter and Ktedonobacter for bacteria and Aspergillus, Cladosporium, Nigrospora, Rigidoporus and Lentinus for fungi. Conditional indoor airborne DNA concentrations (median (range)) were estimated to be 13 (2.6-107) pg/m3 for total DNA, 0.4 (0.05-8.4) pg/m3 for bacterial DNA and 2.3 (1.0-5.1) pg/m3 for fungal DNA. CONCLUSION Conditional airborne concentrations and the relative abundances of selected groups of genera correlate well with occupancy level. Bacterial DNA was found to be more responsive than fungal DNA to differences in occupancy level and indoor environmental conditions.
منابع مشابه
Detection of viruses in used ventilation filters from two large public buildings.
BACKGROUND Viral and bacterial pathogens may be present in the air after being released from infected individuals and animals. Filters are installed in the heating, ventilation, and air-conditioning (HVAC) systems of buildings to protect ventilation equipment and maintain healthy indoor air quality. These filters process enormous volumes of air. This study was undertaken to determine the utilit...
متن کاملOptimal Sensor Placement for Time- Dependent Systems: Application to Wind Studies around Buildings
5 Warm climates pose challenges to building energy consumption and pedestrian comfort. 6 Knowledge of the wind flow around buildings can help address these issues through 7 improving natural ventilation, energy use and outdoor thermal comfort. Computational Fluid 8 Dynamics (CFD) simulations are widely used to predict wind flow around buildings, despite 9 Researcher, Singapore-ETH Centre, Futur...
متن کاملThe role of natural ventilation on reducing indoor radon concentration
Due to the increasing of closed ventilation systems used in buildings, the risk of indoor radon is increased day by day. In this study, we selected two sample rooms to calculate the radon emission coefficient from different levels, radon concentration measured when the natural ventilation was completely closed and compared with the analytical results. The results clearly show the difference in ...
متن کاملComparative Study on the Influence of Window To Wall Ratio on Energy Consumption and Ventilation Performance in Office Building of Temperate Humid Climate: a Case Study in Rash
The natural ventilation and the energy consumption are very important characteristics in buildings. Representation of the patterns for better natural ventilation performance versus lower increase in energy consumption is significant and useful. This study is simulating an office building in the temperate and humid climate of Rasht in Iran, and calculated the annual ventilation and the energy co...
متن کاملPotentials of Vernacular Climatic Solutions (VCS) in Energy Efficiency of Domestic Buildings in Hot and Humid Climate: The Case Study of Bushehr, Iran
This study aims to use vernacular climatic solutions (VCS) of traditional dwellings of Bushehr in common residential buildings of this city in southern Iran and answer to the question that “What is the effect of VCS in terms of energy consumption in these buildings?”. This research was conducted on two levels. At the first level, after selecting an existing model of common residential buildings...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 12 شماره
صفحات -