Introducing a Fresh Cadaver Model for Ultrasound-guided Central Venous Access Training in Undergraduate Medical Education
نویسندگان
چکیده
INTRODUCTION Over the past decade, medical students have witnessed a decline in the opportunities to perform technical skills during their clinical years. Ultrasound-guided central venous access (USG-CVA) is a critical procedure commonly performed by emergency medicine, anesthesia, and general surgery residents, often during their first month of residency. However, the acquisition of skills required to safely perform this procedure is often deficient upon graduation from medical school. To ameliorate this lack of technical proficiency, ultrasound simulation models have been introduced into undergraduate medical education to train venous access skills. Criticisms of simulation models are the innate lack of realistic tactile qualities, as well as the lack of anatomical variances when compared to living patients. The purpose of our investigation was to design and evaluate a life-like and reproducible training model for USG-CVA using a fresh cadaver. METHODS This was a cross-sectional study at an urban academic medical center. An 18-point procedural knowledge tool and an 18-point procedural skill evaluation tool were administered during a cadaver lab at the beginning and end of the surgical clerkship. During the fresh cadaver lab, procedure naïve third-year medical students were trained on how to perform ultrasound-guided central venous access of the femoral and internal jugular vessels. Preparation of the fresh cadaver model involved placement of a thin-walled latex tubing in the anatomic location of the femoral and internal jugular vein respectively. RESULTS Fifty-six third-year medical students participated in this study during their surgical clerkship. The fresh cadaver model provided high quality and lifelike ultrasound images despite numerous cannulation attempts. Technical skill scores improved from an average score of 3 to 12 (p<0.001) and procedural knowledge scores improved from an average score of 4 to 8 (p<0.001). CONCLUSION The use of this novel cadaver model prevented extravasation of fluid, maintained ultrasound-imaging quality, and proved to be an effective educational model allowing third-year medical students to improve and maintain their technical skills.
منابع مشابه
Comparison Between Open and Ultrasonography Guided Venous Access Ports in Children with Malignancy
Background: Long-term central venous access is used in children for various reasons specially for delivering chemotherapy. Since vessels in children have smaller diameters, they are more prone to injury and complications such as thrombosis. Different methods are used for implantation of port-a-cath in children. We aimed to compare the complications of insertion of central venous access ports be...
متن کاملEvidence-based consensus on the insertion of central venous access devices.
There is a lack of standard minimal requirements for the training of insertion techniques and maintenance of central venous access devices (CVADs). An international evidence-based consensus task force was established through the World Congress of Vascular Access (WoCoVA) to provide definitions and recommendations for training and insertion of CVADs. Medical literature published from February 19...
متن کاملCadaver-based abscess model for medical training
Ultrasound imaging is a rapid and noninvasive tool ideal for the imaging of soft tissue infections and is associated with a change of clinician management plans in 50% of cases. We developed a realistic skin abscess diagnostic and therapeutic training model using fresh frozen cadavers and common, affordable materials. Details for construction of the model and suggested variations are presented....
متن کاملUltrasound-guided central venous access: a homemade phantom for simulation.
Various medical specialty organizations and the Agency for Healthcare Research and Quality (AHRQ) have advocated using ultrasonography to guide central venous cannulation. It is surprising then, that very few instructional models have been described to teach this technique. Consequently, we developed a model to teach ultrasound-guided central venous access. This paper presents a recipe for an u...
متن کاملCadaver-based Necrotizing Fasciitis Model for Medical Training
Necrotizing fasciitis is a devastating infectious disease process that is characterized by extensive soft tissue necrosis along deep fascial planes, systemic toxicity, and high mortality. Ultrasound imaging is a rapid and non-invasive tool that can be used to help make the diagnosis of necrotizing fasciitis by identifying several distinctive sonographic findings. The purpose of this study is to...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 17 شماره
صفحات -
تاریخ انتشار 2016