Sample preparation in matrix-assisted laser desorption/ionization mass spectrometry of whole bacterial cells and the detection of high mass (>20 kDa) proteins.
نویسندگان
چکیده
Three sample preparation strategies commonly employed in matrix-assisted laser desorption/ionization mass spectrometry (MALDI-TOFMS) of whole bacterial cells were investigated for the detection of high mass signals; these included the dried droplet, the seed-layer/two-layer, and the bottom-layer methods. Different sample preparation approaches favoured the detection of high- or low-mass proteins. The low-mass peaks were best detected using the bottom-layer method. By contrast, the dried droplet method using a solvent with higher water content, and hence effecting a slower crystallization process, gave the best results for the detection of high-mass signals. Signals up to m/z 158 000 could be detected with this methodology for Bacillus sphaericus. Sodium dodecyl sulphate polyacrylamide gel electrophoresis (SDS-PAGE) analysis of the same extracts used for MALDI-TOFMS showed bands in the molecular weight range in which high-mass peaks were observed in MALDI-MS, suggesting that the high-mass signals are not polymeric adducts of low-mass protein monomers. In addition, one of the high molecular weight proteins (approximately 126 kDa) was putatively identified as an S-layer protein by an in-gel tryptic digest. The bacterial samples spotted on the target wells for MALDI-TOFMS, using the different sample preparation strategies, were examined under a scanning electron microscope and differences were observed between the different strategies, suggesting that the nature of the crystals and the distribution of the analytes amidst the crystals could influence the spectral pattern observed in MALDI-TOFMS of whole bacterial cells. Finally, evidence is presented to indicate that, although the determinants are intact cells, cell lysis occurs both before and during the MALDI process.
منابع مشابه
On-probe sample pretreatment for direct analysis of lipids in gram-positive bacterial cells by matrix-assisted laser desorption ionization mass spectrometry.
On-probe sample pretreatment using trifluoroacetic acid as an additional reagent enabled the direct detection of phospholipids in whole bacteria by means of matrix-assisted laser desorption ionization mass spectrometry for not only gram-negative organisms but also gram-positive ones with a thicker peptidoglycan layer.
متن کاملRapid profiling of E. coli proteins up to 500 kDa from whole cell lysates using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry was used to rapidly detect and profile large proteins from Escherichia coli whole cell lysates in the mass range 25-500 kDa. The bacterial samples were treated with guanidine hydrochloride and Triton X-100 to disrupt and solubilize the large inner membrane proteins. A sample preparation involving a nitrocellulose polym...
متن کاملElectrospray-assisted laser desorption ionization mass spectrometry (ELDI-MS) with an infrared laser for characterizing peptides and proteins.
An electrospray-assisted laser desorption/ionization source with an infrared OPO laser (IR-ELDI) was constructed and optimized for peptide and protein mass spectrometry analysis. Similar to ELDI with an ultraviolet laser, IR-ELDI generates multiply charged molecules for peptides and proteins measured under ambient sampling conditions. Both samples in the dried state and analyte solutions can be...
متن کاملIonic liquids as matrices in microfluidic sample deposition for high-mass matrix- assisted laser desorption/ionization mass spectrometry.
Sample preparation for matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) via a microfluidic deposition device using ionic liquid matrices addresses several problems of standard protocols with crystalline matrices, such as the heterogeneity of sample spots due to the co-crystallization of sample and matrix and the limited capability for high-throughput analysis. Since ioni...
متن کاملDesorption electrospray ionization-mass spectrometry of proteins.
Desorption electrospray ionization-mass spectrometry (DESI-MS) was evaluated for the detection of proteins ranging in molecular mass from 12 to 66 kDa. Proteins were uniformly deposited on a solid surface without pretreatment and analyzed with a DESI source coupled to a quadrupole ion trap mass spectrometer. DESI-MS parameters optimized for protein detection included solvent flow rate, temperat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Rapid communications in mass spectrometry : RCM
دوره 16 13 شماره
صفحات -
تاریخ انتشار 2002