We report on irradiation studies performed on spare production silicon detector modules for the current DØ silicon detector. The lifetime expectations due to radiation damage effects of the existing silicon detector are reviewed. A new upgrade project was started with the goal of a complete replacement of the existing silicon detector. In that context, several investigations on the radiation hardness of new prototype silicon microstrip detectors were carried out. The irradiation on different detector types was performed with 10 MeV protons up to fluences of 1014 p/cm2 at the J.R. Mcdonald Laboratory at Kansas State University. The flux calibration was carefully checked using different normalisation techniques. As a result, we observe roughly 40-50% less radiation damage in silicon for 10 MeV p exposure than it is expected by the predicted NIEL scaling.
منابع مشابه
Status and Performance of the CDF Run II Silicon Detector
The CDF Run II silicon detector with its 8 layers of doubleand single-sided silicon micro strip sensors and a total 722,432 readout channels is one of the largest silicon detector devices currently in use by a HEP experiment. We report our experience commissioning and operating this complex device during the first 4 years of Run II. As the luminosity delivered by the Tevatron collider increases...
متن کاملs . in s - de t ] 2 7 Ju l 2 00 5 The Upgraded DØ Detector DØ Collaboration
The DØ experiment enjoyed a very successful data-collection run at the Fermilab Tevatron collider between 1992 and 1996. Since then, the detector has been upgraded to take advantage of improvements to the Tevatron and to enhance its physics capabilities. We describe the new elements of the detector, including the silicon microstrip tracker, central fiber tracker, solenoidal magnet, preshower de...
متن کاملComparison of Radiation Damage in Silicon Induced by Proton and Neutron Irradiation
The subject of radiation damage to silicon detectors induced by 24-GeV/c protons and nuclear reactor neutrons has been studied. Detectors fabricated on single-crystal silicon enriched with various impurities have been tested. Significant differences in electrically active defects have been found between the various types of material. The results of the study suggest for the first time that the ...
متن کاملD0 Silicon Microstrip Tracker Sergey Burdin for D0 Collaboration
The D0 Run II silicon microstrip tracker (SMT) has 3 square meters of Si area. There are 792,576 channels read out by 6192 SVXIIe chips on 912 read out modules. The SMT provides track and vertex reconstruction capabilities over the full pseudorapidity coverage of the D0 detector. The full detector has been running successfully since April 2002. This presentation covers the experience in commiss...
متن کاملSpring 1997 Issue Icfa Instrumentation Bulletin* Radiation Damage in Ccds Used as Particle Detectors
The development of silicon microstrip detectors for high luminosity application at the Large Hadron Collider (LHC) is described. The technical choices are most severely restricted by the anticipated radiation damage. The arguments are presented which led to the selection of the base line detectors for the silicon tracker of the LHC detector ATLAS: sandwiches of singlesided detectors of n-strips...