A Centrifugal Gradocol Filter.

نویسندگان

  • S D Elek
  • G R Hilson
چکیده

Details of a centrifugal Seitz filter for sterilizing small quantities of fluid were reported some months ago in this journal (Hilson and Elek, 1950). It was then considered that a similar filter, fitted with a gradocol membrane (Elford, 1931) for virus or bacteriophage work where an asbestos pad is not suitable, might be useful. Moreover, a suggestion has been made (Latner and Slack, 1950) that such a device could also be used for the ultrafiltration of chemical mixtures. For these purposes a different design is necessary. The necessary requirements of such an apparatus are that it should be convenient for the handling of small quantities, since often the amount of available infectious material is limited. In addition it is essential that the apparatus should be safe in use, should not cause splashing, and should not leak. Since a wide range of pressures is needed when using gradocol membranes of different porosities both positive-pressure and suction types of apparatus are commonly employed. With centrifugal force, however, the whole range needed can easily be achieved.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Water Retention Value Measurements of Cellulosic Materials Using a Centrifuge Technique

A centrifugal method has been modified and applied to the assessment of water retention value (WRV) in cellulosic materials. Microcrystalline cellulose (MCC), small particles/fibrils isolated from MCC using highpressure homogenizer, and pulp fibers saturated in water were centrifuged at different speeds and times with filter paper and/or a membrane acting as the filter in the WRV measurement se...

متن کامل

Demonstration of a KIER Type CYBAGFILTER System at the Ssangyong Cement Yongwal Plant

A high performance KIER TYPE CYBAGFILTER that combines a fabric filtration and centrifugal dust removal technologies was developed to maintain high performance of the existing bag filter. Based on the performance results obtained from a pilot-scale test unit and fluid dynamics computer simulation, a test CYBAGFILTER of 18,000m3/hr capacity was installed in the clinker calcination process of Yon...

متن کامل

Improved rate and angle estimation through higher accuracy planar motion models

A large number of attitude estimation algorithms assume sensor placement along the axis of rotation. These models assume that all measured accelerations are due to gravity, while in reality this is not always the case. By expanding the system model to accommodate centrifugal and tangential accelerations the attitude can be more accurately estimated. This thesis introduces an approach to model a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 4 2  شماره 

صفحات  -

تاریخ انتشار 1951