Off-resonance magnetisation transfer contrast (MTC) MRI using fast field-cycling (FFC).

نویسندگان

  • Chang-Hoon Choi
  • Gareth R Davies
  • David J Lurie
چکیده

Magnetisation transfer contrast (MTC) is an important MR contrast generating mechanism to characterise the undetectable bound protons indirectly using the decreased signal intensity of the observable free protons. MTC imaging typically employs a range of off-resonance RF pre-saturation pulse with maintaining the RF magnetic field (B(1)) at a specified value. However, this presents a technical difficulty, particularly at low field, because the larger offset frequencies tend to be outside the bandwidth of the RF transmit system, causing B(1) to vary with the frequency offset. Here, we demonstrate a novel off-resonance irradiation method using fast field-cycling which allows switching of the external magnetic field between several chosen strengths, while holding constant the RF frequency and B(1) level. This permits one to avoid the problem of B(1) variation as a function of frequency offset. The results obtained by this new technique are in excellent agreement with those obtained by the conventional technique.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microsoft Word - ISMRM2009-001790.DOC

Introduction The use of fast field-cycling (FFC) with MRI has increased over recent years. The ability to change the external magnetic field (B0) during MR data acquisition affords access to new contrast mechanisms. In this work, we have applied the FFC technique to magnetisation transfer contrast (MTC) imaging experiments. A continuous-wave off-resonance irradiation pulse (or MT pulse) is wide...

متن کامل

Design and construction of an actively frequency-switchable RF coil for fast field-cycling magnetisation transfer contrast MRI

Introduction Magnetisation transfer contrast (MTC) is an important MR contrast generating mechanism to characterise the immobile macromolecular protons using an off-resonance pre-saturation RF pulse (or MT pulse). As the MT effect occurs by MT pulse irradiation, the condition of the MT pulse is the main source to produce MTC. MTC is normally implemented at a fixed magnetic field; however, it ma...

متن کامل

Design and construction of an actively frequency-switchable RF coil for field-dependent Magnetisation Transfer Contrast MRI with fast field-cycling.

Magnetisation Transfer Contrast (MTC) is an important MR contrast-generating mechanism to characterise the MR-invisible macromolecular protons using an off-resonance pre-saturation RF irradiation pulse (or MT pulse). MTC MRI is normally implemented at a fixed magnetic field; however, it may be useful to evaluate changes of the MT effect as a function of external magnetic field strength (B₀). In...

متن کامل

The use of contrast agents with fast field-cycling magnetic resonance imaging.

Fast field-cycling (FFC) MRI allows switching of the magnetic field during an imaging scan. FFC-MRI takes advantage of the T(1) dispersion properties of contrast agents to improve contrast, thus enabling more sensitive detection of the agent. A new contrast agent designed specifically for use with FFC was imaged using both a homebuilt FFC-MRI system and a 3 T Philips clinical MRI scanner. T(1) ...

متن کامل

Rapid field-cycling MRI using fast spin-echo.

PURPOSE Fast field-cycling MRI (FFC-MRI) is a technique that promises to expand upon the diagnostic capabilities of conventional MRI by allowing the main field, B0 , to be varied during a pulse sequence, thus allowing access to new types of endogenous contrast. However, this necessitates longer scan times, which can limit the technique's application to clinical research. In this paper, an adapt...

متن کامل