Estimation of total-body and limb muscle mass in hemodialysis patients by using multifrequency bioimpedance spectroscopy.

نویسندگان

  • George A Kaysen
  • Fansan Zhu
  • Shubho Sarkar
  • Steven B Heymsfield
  • Jack Wong
  • Charoen Kaitwatcharachai
  • Martin K Kuhlmann
  • Nathan W Levin
چکیده

BACKGROUND Skeletal muscle mass can be measured noninvasively with magnetic resonance imaging (MRI), but this is time-consuming and expensive. OBJECTIVE We evaluated the use of multifrequency bioimpedance spectroscopy (BIS) measurements of intracellular volume (ICV) to model total-body skeletal muscle mass (TBMM) and limb skeletal muscle mass in hemodialysis patients. DESIGN TBMM was measured by MRI in 20 male and 18 female hemodialysis patients with a median (range) age of 54 y (33-73 y), weight of 78.9 kg (43.2-120 kg), and body mass index (BMI; in kg/m2) of 27.3 (19.4-46.6). We measured total body water (TBW) by using D2O dilution, extracellular volume (ECV) as bromide space, and ICV as TBW minus bromide space. Total body potassium (TBK) measured as 40K was used as an independent model of TBMM. BIS was used to measure whole-body TBW (ankle to wrist) and TBW in the arms and legs. BIS-estimated ICV was used to construct models to calculate limb muscle mass and TBMM. The latter was compared with models derived from isotopic methods. RESULTS BIS yielded a model for TBMM [TBMM = 9.52 + 0.331 x ICV + 2.77 (male) + 0.180 x weight (kg) - 0.133 x age] (R2 = 0.937, P < 0.0001) as precise as TBK-measured TBMM [TBMM = 1.29 + 0.00453 x TBK (mEq) + 1.46 (male) + 0.144 x weight (kg) - 0.0565 x age] (R2 = 0.930, P < 0.0001) or isotopic methods. BIS models were also developed for measuring leg and arm muscle mass. CONCLUSION BIS provides an estimate of TBMM that correlates well with isotopic methods in approximating values obtained by MRI and can be used to estimate limb muscle mass.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of body composition and normal fluid status using a calf bioimpedance technique.

UNLABELLED The aims of this study in hemodialysis (HD) patients were: 1. To evaluate the relationship of calf bioimpedance with total body composition and fluid status as measured by gold standard methods. 2. To investigate the ability of calf normalized resistivity (CNR) to predict the normal fluid status (dry weight: DW) in a prospective study. In the body composition study (n = 41), fluid st...

متن کامل

Assessment of body composition in dialysis patients by arm bioimpedance compared to MRI and 40K measurements.

This study used multi-frequency bioimpedance spectroscopy (BIS) of the arm and whole body to estimate muscle mass (MM) and subcutaneous adipose tissue (SAT) in 31 hemodialysis (HD) patients comparing these results with magnetic resonance imaging (MRI) and body potassium ((40)K) as gold standards. Total body and arm MM (MM(MRI)) and SAT (SAT(MRI)) were measured by MRI. All measurements were made...

متن کامل

Comparison of bioimpedance methods for estimating total body water and intracellular water changes during hemodialysis.

BACKGROUND The accurate assessment of body fluid volume is important in many clinical situations. Hannan et al. proposed a single-frequency bioimpedance equation (HE) to calculate extracellular water (ECW) and total body water (TBW). There are two equations based on the bioimpedance spectroscopy (BIS) method for the evaluation of body fluid volume: Xitron equations (XE) and body composition spe...

متن کامل

Comparison of Muscle Mass, Total Body Water and Total Body Protein in Type II Diabetics with Healthy Matched Adults by Bioelectrical Impedance Analysis

Background: Bioelectrical impedance analysis (BIA) is a new and rapid technique to validate body composition. Several studies have used this technique to evaluate body compositions, such as muscle mass, in diabetic patients, but the results are very different. This may due the differences between diabetic patients and control group. Therefore, this study aimed to compare the muscle mass of diab...

متن کامل

Volume Estimates in Chronic Hemodialysis Patients by the Watson Equation and Bioimpedance Spectroscopy and the Impact on the Kt/Vurea calculation

Background Accurate assessment of total body water (TBW) is essential for the evaluation of dialysis adequacy (Kt/Vurea). The Watson formula, which is recommended for the calculation of TBW, was derived in healthy volunteers thereby leading to potentially inaccurate TBW estimates in maintenance hemodialysis recipients. Bioimpedance spectroscopy (BIS) may be a robust alternative for the measurem...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The American journal of clinical nutrition

دوره 82 5  شماره 

صفحات  -

تاریخ انتشار 2005