Principles of calibrating the dual - recycled GEO 600

نویسندگان

  • M. Hewitson
  • G. Heinzel
  • J. R. Smith
چکیده

GEO 600 is a dual-recycled interferometric gravitational wave detector which uses advanced optical techniques to achieve its design sensitivity. The peak response of GEO is tunable over a range of frequencies within the detection band of the instrument. The accurate calibration of the detector is an essential step in preparing the data for distribution to the various analysis groups in the community as well as allowing for the extraction of science results. Calibrating the dual-recycled interferometer requires the optical response of the instrument to be determined and corrected for on time scales associated with any fluctuations in the response. Due to the optical readout scheme used in GEO 600, any gravitational wave signals seen by the detector are split between two output signals. This means that, in order to recover a calibrated strain signal that has an optimal signal-to-noise ratio, the two outputs need to be combined preor postcalibration. This article presents a detailed method for calibrating the dual-recycled GEO configuration. The method builds upon the calibration scheme developed to calibrate the power-recycled GEO configuration. The main focus of this article is on the new aspects of the calibration process: on-line measurement, parameterization, and correction of the optical response of the instrument in an on-line, time-domain calibration pipeline. Some discussion is also given regarding the combination of the two main detector output signals in producing an optimal calibrated strain signal. © 2004 American Institute of Physics. [DOI: 10.1063/1.1804831]

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Commissioning , characterization and operation of the dual - recycled GEO 600

The German–British laser-interferometric gravitational-wave detector GEO 600 is currently being commissioned as part of a worldwide network of gravitational-wave detectors. GEO 600 recently became the first kilometrescale interferometer to employ dual recycling—an optical configuration that combines power recycling and signal recycling. We present a brief overview 0264-9381/04/201737+09$30.00 ©...

متن کامل

Calibration of GEO 600 for the S1 science run

Abstract In 2002, the interferometric gravitational wave detector GEO 600 took part in a coincident science run (S1) with other detectors world-wide. When completed, GEO will employ a dual-recycling scheme which will allow its peak sensitivity to be tuned over a range of frequencies in the detection band. Still in the commissioning phase, GEO was operated as a power-recycled Michelson for the d...

متن کامل

Calibration of the dual - recycled GEO 600 detector for the S 3 science run

1 Max-Planck-Institut für Gravitationsphysik (Albert-Einstein-Institut) und Universität Hannover, Außenstelle Hannover, Callinstr. 38, 30167 Hannover, Germany 2 Physics and Astronomy, University of Glasgow, Glasgow G12 8QQ, UK 3 Max-Planck-Institut für Gravitationsphysik, Albert-Einstein-Institut, Am Mühlenberg 1, 14476 Golm, Germany 4 Department of Physics and Astronomy, Cardiff University, PO...

متن کامل

MSR MFn MFe MCn

Dual recycling is the combination of signal recycling and power recycling; both optical techniques improve the shot-noise-limited sensitivity of interferometric gravitational-wave detectors. In addition, signal recycling can reduce the loss of light power due to imperfect interference and allows, in principle, to beat the standard quantum limit. The interferometric gravitational-wave detector G...

متن کامل

Alignment control of GEO 600

Abstract We give an overview of the automatic mirror alignment system of the gravitational wave detector GEO 600. In order to achieve the required sensitivity of the Michelson interferometer, the axes of interfering beams have to be superimposed with a residual angle of the order 10−8 rad. The beam spots have to be centred on the mirrors to minimize coupling of alignment noise into longitudinal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004