Comparison of immunoglobulin determinations in pathological sera by radial immunodiffusion and laser nephelometry.

نویسندگان

  • G Virella
  • H H Fundenberg
چکیده

Immunoglobulins G, A, and M were measured by radial immunodiffusion and by laser nephelometry in sera from 33 patients and in a preparation of purified colostral IgA. In general the results agreed for the two methods, with some exceptions attributed to the physicochemical characteristics of the immunoglobulins assayed: low-molecular-weight (monomeric) IgM gives falsely high values and IgA proteins (consisting predominantly of polymeric molecules) give falsely low values when assayed by radial immunodiffusion. Results from laser nephelometry apparently are not affected by the molecular-size characteristics of the proteins assayed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Laser nephelometry and radial immunodiffusion compared for immunoglobulin quantification in pathological sera.

We evaluated nephelometers from Behring, Hyland, and Beckman for IgG, IgA, and IgM quantitation in sera from patients with monoclonal gammopathies. The intra-batch precision of each instrument for each immunoglobulin class and for different concentrations of the same immunoglobulin was compared to the one obtained with the radial immunodiffusion method. No nephelometer showed a clearly better p...

متن کامل

Concentrations of plasma immunoglobulins in the dog as determined by laser nephelometry. Comparison with radial immunodiffusion and enzyme-linked immunosorbent assay.

Concentrations of immunoglobulins were determined by laser nephelometry and, for comparison, by single radial immunodiffusion assay and a sandwich enzyme-linked immunosorbent assay (ELISA) in plasma samples of normal dogs. Correlation between methods was high, although the mean IgM concentrations determined by laser nephelometry were significantly higher than those determined by the single radi...

متن کامل

Comparison of radial immunodiffusion and laser nephelometry for quantitating some serum proteins.

After quantitating immunoglobulins G, A, and M and complement C3c and C4 in serum by using a laser nephelometer coupled with a data processor, I compared these results with values obtained by an early-readout radial immunodiffusion method. Day-to-day precision was better for nephelometry than for radial immunodiffusion for all proteins analyzed. The average coefficient of variation was 6.0% for...

متن کامل

Six approaches to routine quantification of human monoclonal immunoglobulin M compared.

Six routine techniques for the determination of monoclonal IgM are compared: standard electrophoresis, the Technicon AIP system, Hyland laser nephelometry, Beckman Immunochemistry System, Behring laser nephelometry, and radial immunodiffusion. The data are evaluated by use of a nonparametric statistical analysis of variance by ranks (Friedman test) and Wilcoxon's test. The 27 sera containing mo...

متن کامل

Comparison of protein values in cerebrospinal fluid by nephelometry and radial immunodiffusion.

Various parameters of three radial immunodiffusion systems, a kinetic nephelometer and two laser nephelometers were compared in a measurement of IgG and albumin in cerebrospinal fluid. Greater precision for IgG and albumin determinations was found with two RID systems. Correlation coefficients between methods ranged from 0.71 to 0.94. The generally poor correlations of methods, combined with th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 23 10  شماره 

صفحات  -

تاریخ انتشار 1977