The potential gradient field created by epicardial defibrillation electrodes in dogs.

نویسندگان

  • P S Chen
  • P D Wolf
  • F J Claydon
  • E G Dixon
  • H J Vidaillet
  • N D Danieley
  • T C Pilkington
  • R E Ideker
چکیده

Knowledge of the potential gradient field created by defibrillation electrodes is important for the understanding and improvement of defibrillation. To obtain this knowledge by direct measurements, potentials were recorded from 60 epicardial, eight septal, and 36 right ventricular transmural electrodes in six open-chest dogs while 1 to 2 V shocks were given through defibrillation electrodes on the right atrium and left ventricular apex (RA. V) and on the right and left ventricles (RV .LV). The potential gradient field across the ventricles was calculated for these low voltages. Ventricular fibrillation was electrically induced, and ventricular activation patterns were recorded after delivering high-voltage shocks just below the defibrillation threshold. With the low-voltage shocks, the potential gradient field was very uneven, with the highest gradient near the epicardial defibrillation electrodes and the weakest gradient distant from the defibrillation electrodes for both RA. V and RV .LV combinations. The mean ratio of the highest to the lowest measured gradient over the entire ventricular epicardium was 19.4 +/- 8.1 SD for the RA. V combination and 14.4 +/- 3.4 for the RV .LV combination. For both defibrillation electrode combinations, the earliest sites of activation after unsuccessful shocks just below the defibrillation threshold were located in areas where the potential gradient was weak for the low-voltage shocks. We conclude that there is a markedly uneven distribution of potential gradients for epicardial defibrillation electrodes with most of the voltage drop occurring near the electrodes, the potential gradient field is significant because it determines where shocks fail to halt fibrillation, and determination of the potential gradient field should lead to the development of improved electrode locations for defibrillation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cardiac potential and potential gradient fields generated by single, combined, and sequential shocks during ventricular defibrillation.

BACKGROUND Potential gradient field determination may be a helpful means of describing the effects of defibrillation shocks; however, potential gradient field requirements for defibrillation with different electrode configurations have not been established. METHODS AND RESULTS To evaluate the field requirements for defibrillation, potential fields during defibrillation shocks and the followin...

متن کامل

Epicardial mapping of ventricular defibrillation with monophasic and biphasic shocks in dogs.

To study the mechanism of defibrillation and the reason for the increased defibrillation efficacy of biphasic waveforms, the potential gradient in a 32 x 30-mm region of the right ventricle in 15 dogs was progressively lowered in four steps while a strong potential gradient field was maintained throughout the rest of the ventricular myocardium. The volume of right ventricle beneath the plaque w...

متن کامل

Comparison of defibrillation probability of success curves for an endocardial lead configuration with and without an inactive epicardial patch.

OBJECTIVES This study sought to assess the effect of passive "bystander" epicardial electrodes on defibrillation efficacy. BACKGROUND We hypothesized that an inactive epicardial patch placed in an area of low potential gradient from an endocardial electrode shock might affect defibrillation efficacy through its effects on the shock field and the underlying potential gradient. METHODS We stu...

متن کامل

Effect of epicardial patch electrodes on transthoracic defibrillation.

To improve survival rates in patients undergoing surgical ablative procedures for malignant ventricular tachycardia (VT), a frequent practice is to implant epicardial patch electrodes at the time of map-guided surgery. After operation, patients with inducible VT often receive an automatic internal cardioverter/defibrillator (AICD) implant, whereas patients with noninducible VT usually do not. I...

متن کامل

Comparison of the defibrillation threshold and the upper limit of ventricular vulnerability.

To examine the relationship between the defibrillation threshold and the strength of shocks that induce ventricular fibrillation during the vulnerable period, we determined the defibrillation threshold in 22 open-chest dogs using epicardial defibrillation electrodes with the cathode at the ventricular apex and the anode at the right atrium. We also determined whether there was an upper limit of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 74 3  شماره 

صفحات  -

تاریخ انتشار 1986