Anterior cruciate ligament regeneration using braided biodegradable scaffolds: in vitro optimization studies.

نویسندگان

  • Helen H Lu
  • James A Cooper
  • Sharron Manuel
  • Joseph W Freeman
  • Mohammed A Attawia
  • Frank K Ko
  • Cato T Laurencin
چکیده

The anterior cruciate ligament (ACL) is the most commonly injured intra-articular ligament of the knee, and limitations in existing reconstruction grafts have prompted an interest in tissue engineered solutions. Previously, we reported on a tissue-engineered ACL scaffold fabricated using a novel, three-dimensional braiding technology. A critical factor in determining cellular response to such a graft is material selection. The objective of this in vitro study was to optimize the braided scaffold, focusing on material composition and the identification of an appropriate polymer. The selection criteria are based on cellular response, construct degradation, and the associated mechanical properties. Three compositions of poly-alpha-hydroxyester fibers, namely polyglycolic acid (PGA), poly-L-lactic acid (PLLA), and polylactic-co-glycolic acid 82:18 (PLAGA) were examined. The effects of polymer composition on scaffold mechanical properties and degradation were evaluated in physiologically relevant solutions. Prior to culturing with primary rabbit ACL cells, scaffolds were pre-coated with fibronectin (Fn, PGA-Fn, PLAGA-Fn, PLLA-Fn), an important protein which is upregulated during ligament healing. Cell attachment and growth were examined as a function of time and polymer composition. While PGA scaffolds measured the highest tensile strength followed by PLLA and PLAGA, its rapid degradation in vitro resulted in matrix disruption and cell death over time. PLLA-based scaffolds maintained their structural integrity and exhibited superior mechanical properties over time. The response of ACL cells was found to be dependent on polymer composition, with the highest cell number measured on PLLA-Fn scaffolds. Surface modification of polymer scaffolds with Fn improved cell attachment efficiency and effected the long-term matrix production by ACL cells on PLLA and PLAGA scaffolds. Therefore based on the overall cellular response and its temporal mechanical and degradation properties in vitro, the PLLA braided scaffold pre-coated with Fn was found to be the most suitable substrate for ACL tissue engineering.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Synthesis and characterization of polycaprolactone for anterior cruciate ligament regeneration.

Anterior cruciate ligament (ACL) is the most frequently torn ligament in the knee, and complete healing is unlikely due to lack of vascularization. Current approaches for the treatment of ACL injuries include surgical interventions and grafting, however recent reports show that surgeries have 94% recurrency, and that repaired tissues are biomechanically inferior to the native tissue. These nece...

متن کامل

PLA-poloxamer/poloxamine copolymers for ligament tissue engineering: sound macromolecular design for degradable scaffolds and MSC differentiation.

The treatment of anterior cruciate ligament (ACL) failures remains a current clinical challenge. The present study aims at providing suitable degradable scaffolds for ligament tissue engineering. First, we focus on the design and the evaluation of poly(lactide)/poloxamer or poly(lactide)/poloxamine multiblock copolymers selected and developed to have suitable degradation and mechanical properti...

متن کامل

Ligament tissue engineering: an evolutionary materials science approach.

The anterior cruciate ligament (ACL) is important for knee stabilization. Unfortunately, it is also the most commonly injured intra-articular ligament. Due to poor vascularization, the ACL has inferior healing capability and is usually replaced after significant damage has occurred. Currently available replacements have a host of limitations, this has prompted the search for tissue-engineered s...

متن کامل

Anterior cruciate ligament regeneration using mesenchymal stem cells and silk scaffold in large animal model.

Although in vivo studies in small animal model show the ligament regeneration by implanting mesenchymal stem cells (MSCs) and silk scaffold, large animal studies are still needed to evaluate the silk scaffold before starting a clinical trial. The aim of this study is to regenerate anterior cruciate ligament (ACL) in pig model. The micro-porous silk mesh was fabricated by incorporating silk spon...

متن کامل

Tissue engineering of the anterior cruciate ligament using a braid-twist scaffold design.

The anterior cruciate ligament (ACL) is the most commonly injured intra-articular ligament of the knee. The insufficient vascularization of this tissue prevents it from healing completely after extreme tearing or rupture, creating a need for ACL grafts for reconstruction. The limitations of existing grafts have motivated the investigation of tissue-engineered ACL grafts. A successful tissue-eng...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biomaterials

دوره 26 23  شماره 

صفحات  -

تاریخ انتشار 2005