Performance of an Ultrasonic Ranging Sensor in Apple Tree Canopies

نویسندگان

  • Alexandre Escolà
  • Santiago Planas de Martí
  • Joan Ramón Rosell Polo
  • Jesús Pomar
  • Ferran Camp
  • Francesc Solanelles
  • Felip Gracia
  • Jordi Llorens
  • Emilio Gil
چکیده

Electronic canopy characterization is an important issue in tree crop management. Ultrasonic and optical sensors are the most used for this purpose. The objective of this work was to assess the performance of an ultrasonic sensor under laboratory and field conditions in order to provide reliable estimations of distance measurements to apple tree canopies. To this purpose, a methodology has been designed to analyze sensor performance in relation to foliage ranging and to interferences with adjacent sensors when working simultaneously. Results show that the average error in distance measurement using the ultrasonic sensor in laboratory conditions is ±0.53 cm. However, the increase of variability in field conditions reduces the accuracy of this kind of sensors when estimating distances to canopies. The average error in such situations is ±5.11 cm. When analyzing interferences of adjacent sensors 30 cm apart, the average error is ±17.46 cm. When sensors are separated 60 cm, the average error is ±9.29 cm. The ultrasonic sensor tested has been proven to be suitable to estimate distances to the canopy in field conditions when sensors are 60 cm apart or more and could, therefore, be used in a system to estimate structural canopy parameters in precision horticulture.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Performance Analysis of an Intrinsically Safe Ultrasonic Ranging Sensor

In flammable or explosive environments, an ultrasonic sensor for distance measurement poses an important engineering safety challenge, because the driving circuit uses an intermediate frequency transformer as an impedance transformation element, in which the produced heat or spark is available for ignition. In this paper, an intrinsically safe ultrasonic ranging sensor is designed and implement...

متن کامل

An Ultrasonic Tree Trunk Diameter Caliper

A unique sensing system is described using an ultrasonic transducer for measuring tree trunk diameters in the orchard. Trunk diameters were calculated from the time it took sound waves to travel from the transducer to the trunk and back to the sensor. The device was calibrated with objects ranging in diameter from 1.6 (0.63 inch) to 19.0 cm (7.5 inches). The distance between the transducer and ...

متن کامل

Uncertainty Measurement for Ultrasonic Sensor Fusion Using Generalized Aggregated Uncertainty Measure 1

In this paper, target differentiation based on pattern of data which are obtained by a set of two ultrasonic sensors is considered. A neural network based target classifier is applied to these data to categorize the data of each sensor. Then the results are fused together by Dempster–Shafer theory (DST) and Dezert–Smarandache theory (DSmT) to make final decision. The Generalized Aggregated Unce...

متن کامل

An Investigation of Apple Chlorotic Leaf Spot (ACLSV) and Tomato Ring Spot (ToRSV) in Some Iranian Pear Gardens

Background and Aims: In spite of a long tradition of fruit-tree growing in all provinces of Iran, information on pear (Pyrus communis) tree viruses is scant. In order to identify of the nature of the virus like symptoms and decline in pear trees, we carried out a survey for the occurrence of four important viruses. Materials and Methods: Leaf samples of pear showing virus like symptoms wer...

متن کامل

Ultrasonic-Assisted Matrix Solid-Phase Dispersion and High-Performance Liquid Chromatography as an Improved Methodology for Determination of Oleuropein from Olive Leaves

In this study, ultrasonic-assisted matrix solid-phase dispersion (UA-MSPD) as a new sample preparation method for natural product analysis was developed. Influential parameters of the UA-MSPD method was optimized using oleuropein content of olive leaves as a model analyte. Main parameters of the proposed technique such as ultrasonic time, amplitude and pulse, sorbent material, the ratio of samp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2011