ETNA (Efficiency Transfer for Nuclide Activity measurements) Software for efficiency transfer and coincidence summing corrections in gamma-ray spectrometry
نویسندگان
چکیده
منابع مشابه
Dedicated Monte Carlo Procedures Applied in Gamma- ray Spectrometry Used in Decommissioning of Nuclear Facilities
Because the experimental efficiency calibration is limited to several measurement geometries and cannot be applied directly to all measurement configurations, the efficiency transfer method for the efficiency computation was applied using ETNA software. An approach using efficiencies measured with point sources combined with theoretical procedures was applied for obtaining the peak efficiency ε...
متن کاملOptimization of measurement counting time in Gamma-ray spectrometry of soil samples
The method of optimal measurement counting time in Gamma spectrometry for soil samples was studied. Gamma spectrometry was done based on minimum detectable activity using the HPGe- p type with efficiency of 30% and FWHM 1.7keV (for 1.33 MeV 60Co). The samples were IAEA-RG Th-1, IAEA-RGU-1 and IAEA-RGK-1 prepared in bottles. The measurements were done for 12 different counting times from 5 min t...
متن کاملGenie2000 Cascade Summing Correction Validation Testing
To validate the accuracy and precision of the Genie2000 Cascade Summing Correction method, over 800 archived measurements were made on calibrated sources (filter paper, 20cc liquid scintillation vial, 400 ml beaker and Marinelli beaker) containing cascading (Y and Co) and non-cascading isotopes. These measurements used 133 different high purity germanium detectors that were characterized for us...
متن کاملRadioactivity 6- Radiochemistry The Counting Room: Special Edition
programs. 1 General coincidence summing problems and specific coincidence summing problems encountered when measuring these two radionuclides on filter papers were discussed in the last issue? In order to perform accurate measurements of 134CS and 60Co in liquid samples using Marinelli beakers, coincidence summing effects should be investigated. Liquid samples of 134Cs and 60Co were prepared in...
متن کاملComplex Gamma Ray Spectra Analysis
The gamma ray spectrometry laboratory of the University of Bucharest was designed for the analysis of low-level radioactivity samples. High efficiency shielded HPGe detectors are used. Efficiency calibration is achieved by complementing experimental calibration with Monte Carlo computation carried out using GESPECOR, also applied for the evaluation of coincidence summing corrections. Low detect...