Trilogy-Constrained Acetabular Component for Recurrent Dislocation

نویسندگان

  • Annette Vest Andersen
  • Anne Grete Kjersgaard
  • Søren Solgaard
چکیده

32 patients received a Trilogy- or Trilogy-Longevity-constrained acetabular liner for recurrent dislocations after total hip replacement. The constrained liner was inserted into a well-fixed Trilogy acetabular shell with snap fit. At 1.8-year followup (range 3-63 months), 4 patients had suffered further dislocation(s) (12%), and one patient had revision surgery for a loosened acetabular shell. Radiologic evaluation detected no definitively loose components, but one patient with progressing radiolucent lines around the femoral component and one patient with an acetabular cyst were found, as well as a patient with a loose locking ring (but otherwise no failure). The nineteen patients who were available for the present followup had a mean Harris Hip Score of 81. The constrained liner is an effective method of dealing with recurrent dislocations in well-fixed components.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A constrained acetabular component for recurrent dislocation.

We treated 34 patients with recurrent dislocation of the hip with a constrained acetabular component. Roentgen stereophotogrammetric analysis was performed to assess migration of the prosthesis. The mean clinical follow-up was 3.0 years (2.2 to 4.8) and the radiological follow-up was 2.7 years (2.0 to 4.8). At the latest review six patients had died and none was lost to follow-up. There were fo...

متن کامل

Salvaging unstable or recurrent dislocating total hip arthroplasty with the constrained acetabular component.

PURPOSE To review cases of implantation of constraining acetabular components for unstable or recurrent dislocating total hip arthroplasty at the Department of Orthopaedics, Concord Hospital, Sydney. METHODS A retrospective analysis was performed on prospectively collected data of 13 consecutively enrolled patients. RESULTS From 1989 to 2000, 13 constraining acetabular components were impla...

متن کامل

Omnifit acetabular component: a solution to preventing and treating dislocation.

PURPOSE To assess short- to medium-term outcome of the Omnifit constrained acetabular component in preventing dislocation in at-risk patients after total hip arthroplasty (THA). METHODS 81 patients (mean age, 77 years) underwent either primary or revision THA with an Omnifit constrained acetabular component and were followed up clinically and radiologically for a mean period of 24 months. R...

متن کامل

Constrained acetabular liners in hip revision surgery. A low-cost solution for senile patients.

The objective of this study was to analyze the results of a cemented polyethylene model that captures the hip prosthetic head. In a retrospective study we reviewed 36 cemented constrained acetabular liners implanted in patients older than 75 years (mean 83, SD : 4.4), of which 30 patients were aged 80-90 years and 26 were women. The average period of follow-up of our patients was 25.4 months (1...

متن کامل

Constrained liner in neurologic or cognitively impaired patients undergoing primary THA.

BACKGROUND THA performed in patients with cognitive deficits or neuromuscular diseases has been associated with a high postoperative dislocation rate. The constrained liner reportedly provides stability in patients with recurrent dislocation. However, achieving stability could be offset by early loosening when used in patients with neurologic diseases. QUESTIONS/PURPOSES We therefore asked wh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2013  شماره 

صفحات  -

تاریخ انتشار 2013