Interobserver reliability of neck-mobility measurement by means of the flock-of-birds electromagnetic tracking system.
نویسندگان
چکیده
OBJECTIVE To establish the interobserver reliability for measuring neck mobility in human subjects by means of an electromagnetic tracking device, the Flock-of-Birds system. METHODS Two observers independently and in random order assessed the cervical range-of-motion in 30 subjects with a dysfunction in the neck and shoulder region (symptomatic subjects) and 30 subjects without known pathology (asymptomatic subjects). Measurements included rotation in neutral position, in flexed position and in extended position, flexion-extension, and lateral bending (all active and passive). Reliability was analyzed by intraclass correlation coefficient (ICC) and agreement by limits of agreement and percentage of paired observations within 5 degrees, 10 degrees, and 15 degrees. RESULTS For asymptomatic subjects, the ICC varied from 0.57 to 0.85, and the limits of agreement varied between 14.5 degrees and 27.0 degrees. The percentage of paired observations within 5 degrees, 10 degrees, and 15 degrees ranged from 31% to 57%, 58% to 90%, and 78% to 93%, respectively. For symptomatic subjects, the ICC varied from 0.36 to 0.91, and the limits of agreement varied between 9.6 degrees and 37.8 degrees. The percentage of paired observations within 5 degrees, 10 degrees, and 15 degrees ranged from 17% to 60%, 33% to 93%, and 50% to 97%, respectively. CONCLUSIONS Despite the use of a standardized protocol and a sophisticated measurement system, the interobserver reliability of neck mobility was variable in quality, with reliability being good in rotation in neutral position, flexion-extension, and lateral bending.
منابع مشابه
Variation in the cervical range of motion over time measured by the "flock of birds" electromagnetic tracking system.
STUDY DESIGN Observational longitudinal study. OBJECTIVE To establish the normal variation over time for active and passive cervical range of motion (ROM) measured with the Flock of Birds electromagnetic tracking system (FOB). SUMMARY OF BACKGROUND DATA Data about normal variation of cervical ROM over time are scarce but important for the interpretation of study results. METHODS Forty-eig...
متن کاملEffect of metal and sampling rate on accuracy of Flock of Birds electromagnetic tracking system.
Electromagnetic tracking devices are used in many biomechanics applications. Previous studies have shown that metal located within the working field of direct current electromagnetic tracking devices produces significant errors. However, the effect of sampling rate on the errors produced in a metallic environment has never been studied. In this study, the accuracy of Ascension Technologies' Flo...
متن کاملCalibration of the "Flock of Birds" electromagnetic tracking device and its application in shoulder motion studies.
In this paper the applicability in terms of measurement accuracy of the "Flock of Birds" six D.O.F. electromagnetic tracking device in shoulder research is investigated. Position measurements in a workspace of approximately 1 m3 were performed using a stylus. The andom error at the stylus tip appeared to be 1.86, 1.98 and 2.54 mm for x-, y- and z-coordinate, respectively. The error caused by di...
متن کاملAssessment of the cervical range of motion over time, differences between results of the Flock of Birds and the EDI-320: a comparison between an electromagnetic tracking system and an electronic inclinometer.
The objective of this study was to analyse cervical range of motion, assessed over time by means of a digital inclinometer (EDI-320) and a three-dimensional electromagnetic tracking device (Flock of Birds). The maximum active cervical range of motion was assessed with two measurement devices in three sessions over time, with 6-week intervals. In total, 26 women and 24 men (mean age: 44.4, SD: 9...
متن کاملA Comparison of the Accuracy of an Electromagnetic and a Hybrid Ultrasound-Inertia Position Tracking System
Results of a comparison study of the tracking accuracy of two commercially available wide-range position tracking systems suitable for CAVEs are presented. An experiment was conducted with Flock of Birds and IS-900 tracking systems installed in the same CAVE environment to compare their accuracy. Another experiment was performed with a newly deployed IS-900 to investigate the impact of differen...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of manipulative and physiological therapeutics
دوره 28 6 شماره
صفحات -
تاریخ انتشار 2003