Comparison of working length determination with radiographs and four electronic apex locators.

نویسندگان

  • J P Vieyra
  • J Acosta
چکیده

AIM To evaluate the accuracy of the Root ZX, Elements-Diagnostic, Precision AL and Raypex 5 electronic apex locators when compared to radiographs for locating the apical constriction. METHODOLOGY The apical constriction of 693 canals in 245 maxillary and mandibular teeth was located in vivo with four electronic apex locators (EALs) and radiographically. After extraction the actual location of the apical constriction was determined visually and with magnification. A paired samples t-test, X2 test and a repeated measure anova at the 0.05 level of significance were used to determine differences between the groups. RESULTS For anterior teeth, the Root ZX, Elements, Precision AL, Raypex 5 and radiographs located the apical constriction 89.09%, 83.63%, 85.45%, 81.81% and 32.72% of the time, respectively. For premolar teeth, the Root ZX, Elements, Precision AL, Raypex 5 and radiographs located the apical constriction 75%, 61.60%, 64.28%, 61.60% and 32.14% of the time, respectively. For molar teeth, the Root ZX, Elements, Precision AL, Raypex 5 and radiographs located the apical constriction 69.01%, 50.49%, 65.40%, 43.93% and 14.59% of the time, respectively. There was no statistically significant difference between the four EALs (P = 0.05). CONCLUSION Measuring the location of the apical constriction using the four apex locators was more accurate than radiographs and would reduce the risk of instrumenting and filling beyond the apical foramen.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Working Length Determination Using Apex Locator and Conventional Radiography in Curved Canals-an In Vitro Study

Introduction: The exact measurement of the root canal length is of great importance in root canal therapy. Although, determination of the root canal length through radiography is the most common method, recently electronic apex locators are being used to determine working length and decrease the number of radiographs. The purpose of this study was to compare the accuracy of an electronic apex l...

متن کامل

In vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination

In vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination Dr. Hasheminia, S.M.* - Dr. Jafari, N.** *Associate Professor of Endodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ** Dentist. Abstract Background & Aim: Radiography is still the common method of measuring working length in root canal therapy. While, gag refl...

متن کامل

مقایسه دقت دستگاه‌های اپکس یاب الکترونیکی ZX Root،Novapex  در مقایسه با رادیوگرافی در شرایط in vivo

Background and Aims: Working length determination and remaining this length is of great importance in root canal therapy. Recently, electronic apex locators are being used to determine working length and decrease the number of radiographs. The purpose of this study was to compare the sensitivity of Root ZX and Novapex electronic apex locators with radiography in a clinical study. Materials and...

متن کامل

Accuracy of Different Methods of Working Length Determination in Endodontics

Background: Accurate assessment of the working length determines the success and prognosis of endodontic treatment. There are no systematic reviews comparing the accuracy of different methods of working length determination in endodontics Aim: To evaluate clinical studies on the accuracy of different methods used for working length determination in endodontics. Search strategy: Search was condu...

متن کامل

ارزیابی دقت دو دستگاه آپکس یاب الکترونیکی (Electronic Apex Locator) از نسل چهارم در تعیین طول کانال (In-vivo)

Background and Aim: Determining correct working length in root canal therapy is of great importance in successful treatment. The purpose of this study was to compare the accuracy of two electronic apex locators of fourth generation, Raypex4 and Apit7, in determining working length in vivo. Materials and Methods: In this test evaluation study performed at Dental School of Tehran University, a to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International endodontic journal

دوره 44 6  شماره 

صفحات  -

تاریخ انتشار 2010