Quantification of water permeability can improve the accuracy of perfusion measurements obtained with arterial spin labeling (ASL) methods, and may provide clinically relevant information regarding the functional status of the microvasculature. The amount of labeled water in the vascular and tissue compartments in an ASL experiment can be estimated based on their distinct diffusion characteristics, and in turn, water permeability determined from the relative vascular and tissue contributions. In the present study, a hybrid magnetic resonance imaging technique was introduced by marrying a continuous ASL method with a twice-refocused spin-echo diffusion sequence. Series of diffusion-weighted ASL signals were acquired with systematically varied b values. The signals were modeled with fast and slow decaying components that were associated with the vascular and tissue compartments, respectively. The relative amount of labeled water in the tissue compartment increased from 61% to 74% and to 86% when the postlabeling delay time was increased from 0.8 to 1.2 and to 1.5 secs. With a b value of 50 secs/mm2, the capillary contribution (fast component) of the ASL signal could be effectively minimized. Using the single-pass approximation model, the water permeability of gray matter in the human brain was estimated based on the derived relative water fractions in the tissue and microvasculature. The potential for in vivo magnetic resonance mapping of water permeability was showed using two diffusion weighted ASL measurements with b=0 and 50 secs/mm2 in both healthy subjects and a case of brain tumor.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

When Perfusion Meets Diffusion – in vivo Measurement of Water Extraction and Permeability in Human Brain

Introduction While water was initially considered as a freely diffusible tracer in arterial spin labeling (ASL) perfusion MRI, emerging evidence suggested a limited degree of water exchange between the vascular (capillary) and tissue compartments (1, 2). Quantification of water extraction fraction and permeability is important for accurate perfusion quantification in ASL methods, and may provid...

متن کامل

Quantification of blood-brain-barrier permeability dysregulation and inflammatory activity in MS lesions by dynamic-contrast enhanced MR imaging

Objective: Measurement of blood-brain permeability dysfunction in active and chronic MS lesions with T1-weighted dynamic contrast-enhanced MRI to show variation in inflammatory activity Background: blood-brain-barrier perfusion characterization impaired in MS as some studies have shown recently buta comparison between perfusion parameters in contrast-enhanced and non-enhanced lesions not have ...

متن کامل

Intracellular water lifetime measured by diffusion weighted and dynamic contrast enhanced MRI

Introduction: Intracellular water lifetime (τi) is closely related to membrane permeability and intracellular water diffusivity in addition to size and shape of the cells [1, 2]. The importance of this parameter is paramount in understanding MR data, particularly for diffusion and perfusion experiments. Dynamic contrast enhanced (DCE)-MRI of a diffusible tracer has been widely used for diagnosi...

متن کامل

In vivo measurement of blood-brain barrier permeability.

This unit describes various protocols for the in vivo quantitation of drug permeability across the rodent blood-brain barrier. Methods for the measurement of drug influx and efflux are described, and support protocols are provided for determining intravascular capillary volume and cerebral perfusion flow. An in situ perfusion technique is also provided for assessing whether transport of a test ...

متن کامل

Quantification of the effect of water exchange in dynamic contrast MRI perfusion measurements in the brain and heart.

Measurement of myocardial and brain perfusion when using exogenous contrast agents (CAs) such as gadolinium-DTPA (Gd-DTPA) and MRI is affected by the diffusion of water between compartments. This water exchange may have an impact on signal enhancement, or, equivalently, on the longitudinal relaxation rate, and could therefore cause a systematic error in the calculation of perfusion (F) or the p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism

دوره 27 4  شماره 

صفحات  -

تاریخ انتشار 2007