A Monte Carlo study of ligand-dependent integrin signal initiation

نویسندگان

  • Federico Felizzi
  • Dagmar Iber
چکیده

Integrins are allosteric cell adhesion receptors that control many important processes, including cell migration, proliferation, and apoptosis. Ligand binding activates integrins by stabilizing an integrin conformation with separated cytoplasmic tails, thus enabling the binding of proteins that mediate cytoplasmic signaling. Experiments demonstrate a high sensitivity of integrin signaling to ligand density and this has been accounted mainly to avidity effects. Based on experimental data we have developed a quantitative Monte Carlo model for integrin signal initiation. We show that within the physiological ligand density range avidity effects cannot explain the sensitivity of cellular signaling to small changes in ligand density. Src kinases are among the first proteins to be activated, possibly by trans auto-phosphorylation. We calculate the extent of integrin and ligand clustering as well as the speed and extent of Src kinase activation by trans auto-phosphorylation or direct binding at different experimentally monitored ligand densities. We find that the experimentally observed ligand density dependency can be reproduced if Src kinases are activated by trans auto-phosphorylation or some other mechanism limits integrin-dependent Src kinase activation. We propose that Src kinase and thus cell activation by trans auto-phosphorylation may provide a mechanism to enable ligand-density dependent responses at physiological ligand densities. The capacity to detect small differences in ligand density at a ligand density that is large enough to permit cell adhesion is likely to be important

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characteristics of lead glass for radiation protection purposes: A Monte Carlo study

Background: Lead glass has a wide variety of applications in radiation protection. This study aims to investigate some characteristics of lead glass such as the γ-ray energy-dependent mass and linear attenuation coefficients, the half-value layer thickness, and the absorbed dose distribution for specific energy. Materials and Methods: The attenuation parameters of different lead glass types aga...

متن کامل

Stabilizing to disruptive transition of focal adhesion response to mechanical forces.

Strong mechanical forces can, obviously, disrupt cell-cell and cell-matrix adhesions, e.g., cyclic uniaxial stretch induces instability of cell adhesion, which then causes the reorientation of cells away from the stretching direction. However, recent experiments also demonstrated the existence of force dependent adhesion growth (rather than dissociation). To provide a quantitative explanation f...

متن کامل

Evaluation of Lung Dose in Esophageal Cancer Radiotherapy Using Monte Carlo Simulation

Background and purpose: Radiation therapy make an important contribution in the control and treatment of cancers. Lungs are the main organs at risk in esophageal cancer radiotherapy. Difference between the dose distribution due to the treatment planning system (TPS) and the patient's body dose is dependent on the calculation of the treatment planning system algorithm, which is more pronounced i...

متن کامل

MOCA ARM: Analog Reliability Measurement based on Monte Carlo Analysis

Due to the expected increase of defects in circuits based on deep submicron technologies, reliability has become an important design criterion. Although different approaches have been developed to estimate reliability in digital circuits and some measuring concepts have been separately presented to reveal the quality of analog circuit reliability in the literature, there is a gap to estimate re...

متن کامل

Monte Carlo calculation of shielding properties of newly developed heavy concretes for megavoltage photon beam spectra used in radiation therapy

Introduction: Globally, the need for radiotherapy as a part of cancer management increases every year. Thus, the shielding for megavoltage radiotherapy rooms is of great importance. Materials and Methods: In the present study, 14 types of developed high-density concrete with densities ranging from 2.45 to 5.11 were simulated by using Monte Carlo method. The linear attenuation coefficient and t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010