Use of a quantitative pedicle screw accuracy system to assess new technology: Initial studies on O-arm navigation and its effect on the learning curve of percutaneous pedicle screw insertion

نویسندگان

  • Joseph A. Sclafani
  • Gilad J. Regev
  • Jonathan Webb
  • Steven R. Garfin
  • Choll W. Kim
چکیده

BACKGROUND A quantitative screw accuracy system is proposed that allows for high-fidelity discrimination between various methods of pedicle screw insertion. Our purpose was to study the utility of a quantitative screw accuracy scoring system to assess new imaging technologies and their effects on the minimally invasive spine learning curve. METHODS By use of a hypothetical "perfect screw," a scoring system is proposed that may be used to compare the position of a small number of screws inserted according to a desired optimal position. This study incorporates a retrospective review of imaging studies for 10 patients who underwent percutaneous pedicle screw placement with either navigation-assisted O-arm imaging or navigation-assisted C-arm imaging. For the learning-curve portion of the study, 2 cadaveric adult torsos were used for instrumentation. Computed tomography imaging studies were used in both studies to assess screw position in the pedicle and vertebral body in relation to an optimal screw by use of a quantitative scoring system to rate accuracy. RESULTS The quantitative scoring system allowed a statistically significant accuracy difference to be ascertained between 2 different technologies using fewer data points than previously published methods. When this screw scoring system is applied to minimally invasive percutaneous pedicle screw insertion, an optimal screw position can be achieved with greater accuracy through navigation-assisted technology (O-arm with computer-assisted navigation). When the O-arm with computer-assisted navigation was used by a novice surgeon learning the technique of percutaneous screw insertion, screws were inserted in a shorter period without loss of accuracy. In contrast, use of the traditional C-arm fluoroscopy leads to a loss of accuracy with faster insertion times. Increased accuracy can be seen clinically when compared with fluoroscopic navigation. CONCLUSIONS The use of a quantitative scoring system allows for rapid assessment of screw accuracy. As additional technologies and new teaching techniques for pedicle screw insertion are developed, this scoring system may be useful as an early assessment tool.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pedicle violation and Navigational errors in pedicle screw insertion using the intraoperative O-arm: A preliminary report

BACKGROUND Use of computer-assisted insertion of pedicle screws has some advantages owing to the reportedly decreased incidence of pedicle breach and clinical events. Registration-based methods based on preoperative computed tomography imaging, 2D fluoroscopy, and 3D fluoroscopy are the most popular, however each has its limitations. O-arm-based navigation, which uses intraoperative acquisition...

متن کامل

Accuracy of computer-assisted pedicle screw placement. An in vivo computed tomography analysis.

STUDY DESIGN A computer-assisted planning and visualization system (the Orthopaedic Surgery Planning System) was tested for pedicle screw insertion in vivo. OBJECTIVES To evaluate the system's applicability for regular intraoperative use and its accuracy for pedicle screw placement in vivo. SUMMARY OF BACKGROUND DATA Pedicle screw placement poses considerable anatomic and biomechanical risk...

متن کامل

Clinical Evidence eGuide O-arm® Imaging System

Park P, Foley KT, Cowan JA, Marca FL. Department of Neurosurgery, University of Michigan Health System, Ann Arbor, MI, USA Surg Neurol Int. 2010 Aug Background: Pedicle screw misplacement is relatively common, with reported rates ranging up to 42%. Although computer-assisted image guidance (CaIG) has been shown to improve accuracy in open spinal surgery, its use in minimally invasive procedures...

متن کامل

Pedicle screw placement with O-arm and stealth navigation.

Various navigation systems are available to aid pedicle screw placement. The O-arm replaces the need for fluoroscopy and generates a 3-dimensional volumetric dataset that can be viewed as transverse, coronal, and sagittal images of the spine, similar to computed tomography (CT) scanning. The dataset can be downloaded to the Stealth system (Medtronic Navigation, Louisville, Colorado) for real-ti...

متن کامل

Accuracy of Pedicle Screw Placement in Scoliosis Surgery: A Comparison between Conventional Computed Tomography-Based and O-Arm-Based Navigation Techniques

STUDY DESIGN Retrospective study. PURPOSE We compared the accuracy of O-arm-based navigation with computed tomography (CT)-based navigation in scoliotic surgery. OVERVIEW OF LITERATURE No previous reports comparing the results of O-arm-based navigation with conventional CT-based navigation in scoliotic surgery have been published. METHODS A total of 222 pedicle screws were implanted in 29...