Triiodothyron me (T3)-upta ke values in selected human serum pools were compared by use of Abbott’s “Trisorb,” Mallinckrodt Nuclear’s “Res0-Mat,” Curtis Nuclear’s “Tri-lonex,” and a standard procedure. In addition, interlaboratory variation was measured among laboratories using the Abbott and Mallinckrodt procedures. Study of methodological variables indicated that incubation time and temperature affect 13 measurement. The Abbott procedure is most liable to variations caused by either time or temperature changes; the Mallinckrodt and Curtis methods are least liable to variations caused by changes in time and temperature, respectively. Between-run variation for sera with low 13-uptake values was greater than within-run variation as measured by the Abbott, Mallinckrodt, or standard procedure. For sera with high T3-uptake values, between-run variation and within-run variation are similar; with the Curtis method this was true for all serum pools. We and the reference laboratories found the Abbott method to be most sensitive in detecting changes in T3-uptake values of samples in the “hyperthyroid” range.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Variability of CSF Alzheimer’s Disease Biomarkers: Implications for Clinical Practice

BACKGROUND Cerebrospinal fluid (CSF) biomarkers are increasingly being used for diagnosis of Alzheimer's disease (AD). OBJECTIVE We investigated the influence of CSF intralaboratory and interlaboratory variability on diagnostic CSF-based AD classification of subjects and identified causes of this variation. METHODS We measured CSF amyloid-β (Aβ) 1-42, total tau (t-tau), and phosphorylated t...

متن کامل

Interlaboratory and intralaboratory variability in pulmonary function testing. A 13-year study using a normal biologic control.

The purpose of this study was to document the precision with which measurements can be made on a normal subject as a "biologic control" when comparisons are made both on an intralaboratory and interlaboratory basis. One individual had a total of about 300 routine pulmonary function measurements in 22 laboratories during a 13-year period. In this study, significant variation was found in interla...

متن کامل

Effect of calibration on dispersion of glycohemoglobin values determined by 111 laboratories using 21 methods.

One hundred eleven laboratories, using 21 different methods based on five different principles, determined glycohemoglobin (GHb) percentages in two identical series of six lyophilized hemolysates and three similarly processed calibrators, distributed 3 months apart. To assign GHb percentages to calibrators, we used HbA1c results from nine participants who used the Bio-Rad Diamat high-performanc...

متن کامل

Intra- and interlaboratory sources of imprecision in drug measurements by different techniques.

We compared the intra- and interlaboratory precision of seven techniques used to measure eight antiepileptic drugs, digoxin, and theophylline by using data from the international Healthcontrol external quality-assessment scheme. Scheme participants were supplied blind with 6 or 12 sets of duplicate lyophilized serum samples. Each set contained different drug concentrations, and duplicates were ...

متن کامل

Interlaboratory comparison of lead and cadmium in blood, urine, and aqueous solutions.

Analysis for lead and cadmium in biological liquids (blood and urine) is difficult. Results of such analyses from five laboratories are compared for samples with known additions of lead and cadmium. The data, evaluated in terms of inter- and intralaboratory reproducibility and accuracy, suggest that laboratories should voluntarily participate in quality control programs. Users of routine labora...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 18 11  شماره 

صفحات  -

تاریخ انتشار 1972