A new standardized-automatic method for bone-to-implant contact histomorphometric analysis based on backscattered scanning electron microscopy images.

نویسندگان

  • Carolina Manresa
  • Manel Bosch
  • María Cristina Manzanares
  • Patricia Carvalho
  • José Javier Echeverría
چکیده

AIM To establish an image analysis procedure for measuring the bone-to-implant contact (BIC) by a systematic non-subjective approach based on backscattered scanning electron microscopy (BS-SEM) images. MATERIAL AND METHODS A total of 36 dental implants (9 mm length, Ø 4.0 mm with a SBM surface) were implanted in six beagle dog mandibles. The implants were removed after 1, 2, 4, 6, and 8 weeks and then embedded in resin and cut along their long axis. Sample observation was performed by BS-SEM, acquiring 10 to 16 images per sample. Image processing and BIC determination were performed using the Fiji image processing package. Images were stitched, filtered, and thresholded to obtain a binary image of the whole implant that finally was dilated and outlined. The length of this outline was measured as the maximum possible BIC. The regions of coincidence between this line and the bone were measured as the real BIC. RESULTS The proposed methodology for BIC determination, based on SEM, which has a much higher resolution than optical microscopy, allows the acquisition of highly discriminative images with great contrast between implant and bone. The high resolution and high contrast in SEM images provide more accurate results than those obtained by classical methods. Furthermore, the methodology of image analysis described in this study delineates precisely and automatically the contour of the implant, which results in non-biased measurements. The average percentage of BIC was 35%, ranging from 24.7 to 45.5%. These values were similar to the results documented in the literature for implants of similar roughness in animal models. CONCLUSIONS A novel, non-subjective, and systematic method for measuring BIC is described based on BS-SEM images. The proposed methodology minimizes the shortcomings of the results obtained by previously described methods.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Physicochemical Characterization and In Vivo Evaluation of Amorphous and Partially Crystalline Calcium Phosphate Coatings Fabricated on Ti-6Al-4V Implants by the Plasma Spray Method

Objective. To characterize the topographic and chemical properties of 2 bioceramic coated plateau root form implant surfaces and evaluate their histomorphometric differences at 6 and 12 weeks in vivo. Methods. Plasma sprayed hydroxyapatite (PSHA) and amorphous calcium phosphate (ACP) surfaces were characterized by scanning electron microscopy (SEM), interferometry (IFM), X-ray diffraction (XRD)...

متن کامل

FGF‐2 promotes initial osseointegration and enhances stability of implants with low primary stability

OBJECTIVES The aim of this study was to examine the effect of basic fibroblast growth factor (FGF-2) on osseointegration of dental implants with low primary stability in a beagle dog model. MATERIALS AND METHODS Customized titanium implants that were designed to have low contact with the existing bone were installed into the edentulous mandible of beagle dogs. To degrade the primary stability...

متن کامل

New laser-treated implant surfaces: a histologic and histomorphometric pilot study in rabbits.

PURPOSE The purpose of this study was to confirm the validity of laser treated implant surfaces, with regard to high superficial purity preservation and to extremely regular and uniform roughness surfaces. METHODS In this in vivo study, seven different laser treated implant surfaces were analyzed. A diode-pumped solid state source laser, in a Q-Switch output mode, was used at various waveleng...

متن کامل

Volumetric quantification of bone-implant contact using micro-computed tomography analysis based on region-based segmentation

PURPOSE We have developed a new method of segmenting the areas of absorbable implants and bone using region-based segmentation of micro-computed tomography (micro-CT) images, which allowed us to quantify volumetric bone-implant contact (VBIC) and volumetric absorption (VA). MATERIALS AND METHODS The simple threshold technique generally used in micro-CT analysis cannot be used to segment the a...

متن کامل

The comparison between implant stability quotient and bone-implant contact revisited: an experiment in Beagle dog.

BACKGROUND Resonance frequency analysis (RFA) is applied clinically for the assessment of implant stability, and the relevance of this application is widely accepted. However, the relationship between resonance frequency (RF) and other parameters of implant stability, such as the histomorphometrical bone-to-implant contact (BIC) parameter, has become controversial in the last decade. OBJECTIV...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical oral implants research

دوره 25 6  شماره 

صفحات  -

تاریخ انتشار 2014