NICMOS Focus and HST Breathing

نویسنده

  • A. Suchkov
چکیده

The program 7608 monitored on a biweekly basis NICMOS camera foci from June 9, 1997, through February 18, 1998. Each of the biweekly observations included 17 measurements of focus position (focus sweeps), individually for each of the three cameras. The measurements for camera 1 and camera 3 foci covered one or two HST orbital periods. Comparison of these measurements with the predictions of the three OTA focus breathing models has shown the following. (1). Focus variations seen in NICMOS focus sweeps correlate well with the OTA focus thermal breathing as predicted by breathing models (“4– temperature”, “full–temperature”, and “attitude” models). Thus they can be attributed mostly to the HST orbital temperature variation. (2). The amount of breathing (breathing amplitude) has been found to be on average larger in the first orbit after a telescope slew to a new target. This is explained as being due to additional thermal perturbations caused by the change in the HST attitude as the telescope repoints to a new target. (3). In the first orbit, the amount of focus change predicted by the 4-temperature model is about the same as that seen in the focus sweeps data (breathing scale factor ~1). However the full–temperature model predicts a two times smaller breathing amplitude (breathing scale factor ~1.7). This suggests that the light shield temperatures are more responsive to the attitude change than temperatures from the other temperature sensors. The results of this study may help to better understand the HST thermal cycles and to improve the models describing the impact of those on both the OTA and NICMOS focus.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

NICMOS Two Gyro Mode Coronagraphic Performance

In preparation for the Hubble Space Telescope (HST) entry into Two Gyro Mode (TGM) operations, the NICMOS coronagraphic performance was assessed during the February 21, 2005 TGM on orbit test (ID: 10448) in two filter bands (F110W and F160W). The gyroscope pair 2-4 was used for the TGM test. Observations were obtained of a previously observed calibration target (GJ517; sp.type=K5Ve) coronagraph...

متن کامل

NICMOS Coronagraphy: Recalibration and the NICMOS Legacy Archive PSF Library

NICMOS coronagraphy, with well-matched template Point Spread Function (PSF) subtraction, probes the closest environments of occulted targets with the highest imaging sensitivity in intrinsically high contrast fields at the smallest radial distances afforded, uniquely, by HST. NICMOS PSF-subtracted coronagraphy has been invoked in a wide variety of HST programs with science themes as divergent a...

متن کامل

TinyTim modeling of NICMOS PSF subtraction: effects of focus breathing, cold mask wiggling, and color variations

We conduct TinyTim modeling of NICMOS camera 2 PSFs to assess limits to the accuracy of PSF subtraction imposed by color dependence, OTA focus breathing, and cold mask wiggling. The results suggest that effects of both cold mask wiggling and focus breathing can be described as a noise in a PSF-subtracted image, well above 20% of the PSF signal in narrow band filters, with a spatial scale of a f...

متن کامل

DOMAINS OF OBSERVABILTY IN THE NEAR-INFRARED with HST/NICMOS and (ADAPTIVE OPTICS AUGMENTED) LARGE GROUND-BASED TELESCOPES

This report has been prepared at the request of STScI. It is intended to serve as a guide for HST proposers and TAC panel reviewers in evaluating the need for HST/NICMOS to accomplish the scientific goals of programs under consideration in specific observational domains. In the years since the first incarnation of NICMOS, ground-based technical capabilities in support of challenging astronomica...

متن کامل

Highlights from Hst/nicmos

The Near-Infrared Camera and Multi-Object Spectrometer (NICMOS) was installed in the Hubble Space Telescope in February 1997. After twenty-two months of operation the 110 kg supply of solid N2, which cooled the NICMOS-3 HgCdTe detectors, was exhausted. The cryostat warmed up leaving the instrument in an electromechanically functional, but scientifically non-viable, passive state. Following a th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1998