Wire System Aging Assessment and Condition Monitoring Using Line Resonance Analysis (LIRA)

نویسندگان

  • Paolo F. Fantoni
  • Gary J. Toman
چکیده

This paper describes a method for wire system condition monitoring, developed at the IFE Halden Reactor Project, which is based on Frequency Domain Reflectometry. This method resulted in the development of a system called LIRA (LIne Resonance Analysis), which can be used on-line to detect local or global changes in the cable electrical parameters as a consequence of insulation faults or degradation. This paper presents some results achieved in field experiments on signal cables for nuclear installations, in USA and Europe.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

NKS-130, Wire System Aging Assessment and Condition Monitoring (WASCO)

Nuclear facilities rely on electrical wire systems to perform a variety of functions for successful operation. Many of these functions directly support the safe operation of the facility; therefore, the continued reliability of wire systems, even as they age, is critical. Condition Monitoring (CM) of installed wire systems is an important part of any aging program, both during the first 40 year...

متن کامل

Optimal Electroporation Condition for Small Interfering RNA Transfection into MDA-MB-468 Cell Line

Background: Electroporation is a valuable tool for small interfering RNA (siRNA) delivery into cells because it efficiently transforms a wide variety of cell types. Since electroporation condition for each cell type must be determined experimentally, this study presents an optimal electroporation strategy to reproducibly and efficiently transfect MDA-MB 468 human breast cancer cell with siRNA. ...

متن کامل

Availability analysis of mechanical systems with condition-based maintenance using semi-Markov and evaluation of optimal condition monitoring interval

Maintenance helps to extend equipment life by improving its condition and avoiding catastrophic failures. Appropriate model or mechanism is, thus, needed to quantify system availability vis-a-vis a given maintenance strategy, which will assist in decision-making for optimal utilization of maintenance resources. This paper deals with semi-Markov process (SMP) modeling for steady state availabili...

متن کامل

Sensitivity Assessment of Lightning Protection Device Aging Effect on Distribution Substation Insulation

 Insufficient electrical endurance of equipment and insulation failure against overvoltage is one of the most effective reasons for failure the power line. Lightening, switching or other disruptive parameters can cause line outage or distribution substation failure. There are different devices used to improve the safety, reliability, and power quality of the system. Surge arresters are one of t...

متن کامل

Condition Assessment of Metal Oxide Surge Arrester Based on Multi-Layer SVM Classifier

This paper introduces the indicators for surge arrester condition assessment based on the leakage current analysis. Maximum amplitude of fundamental harmonic of the resistive leakage current, maximum amplitude of third harmonic of the resistive leakage current and maximum amplitude of fundamental harmonic of the capacitive leakage current were used as indicators for surge arrester condition mon...

متن کامل