Improved Slice Excitation for Ultra-short TE Imaging with B0 and Linear Eddy Current Correction

نویسندگان

  • A. Lu
  • B. L. Daniel
  • K. B. Pauly
چکیده

INTRODUCTION MR imaging with ultra short echo times (UTEs) are of increasing interest to visualize tissues with short T2 or T2*, such as cartilage and ligaments, or monitoring the temperature during cryosurgery [1]. To achieve ultra-short TEs, a self-refocused half RF is usually used for excitation [2]. However, eddy currents induced by the selective gradient can result in undesirable slice profile and therefore limit the applications of this technique. Though several techniques have been proposed to compensate for eddy currents [1,3], a robust approach is still needed. Here we present an effective method to compensate for both B0 eddy currents and linear eddy currents, and our results demonstrate significantly improvement in slice selectivity.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correcting for Strong Eddy Current Induced B0 Modulation Enables Two-Spoke RF Pulse Design with Parallel Transmission: Demonstration at 9.4T in the Human Brain

Successful implementation of homogeneous slice-selective RF excitation in the human brain at 9.4T using 16-channel parallel transmission (pTX) is demonstrated. A novel three-step pulse design method incorporating fast real-time measurement of eddy current induced B0 variations as well as correction of resulting phase errors during excitation is described. To demonstrate the utility of the propo...

متن کامل

Software Compensation of Eddy Current Fields in Higher Order Dynamic Shimming

Introduction Dynamic Shimming (DS) is a technique for obtaining optimal B0 field homogeneity over a volume by updating the shim coil currents for every slice in a multislice acquisition in real time [1, 2]. While DS can theoretically produce better B0 homogeneity for each imaging subvolume than static, global volume shimming methods, its performance may be limited by eddy current fields produce...

متن کامل

Background Gradient Correction using Excitation Pulse Profile for Fat and T2* Quantification in 2D Multi-Slice Liver Imaging

Purpose : The objective of this study was to develop background gradient correction method using excitation pulse profile compensation for accurate fat and T2* quantification in the liver. Materials and Methods: In liver imaging using gradient echo, signal decay induced by linear background gradient is weighted by an excitation pulse profile and therefore hinders accurate quantification of T2* ...

متن کامل

Correcting High Order Eddy Current Induced Distortion for Diffusion Weighted Echo Planar Imaging

INTRODUCTION It is well known that diffusion weighted echo planar imaging (DW-EPI) often suffers from direction dependent distortions due to diffusion gradient generated eddy currents. These distortions, if not corrected, can lead to misregistration among DW images of different directions and inaccuracies in any post processing operations involving DW image combination. Dual spin echo DW-EPI [1...

متن کامل

Improved half RF slice selectivity in the presence of eddy currents with out-of-slice saturation.

Ultrashort echo time imaging with half RF pulse excitation is sensitive to eddy currents induced by the slice-select gradient that distorts the half pulse slice profile. This work demonstrates improvements in the half pulse profile by using spatial saturation on both sides of the imaged slice to suppress the out-of-slice magnetization. This effectively improves the selectivity of the half pulse...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005