Human anterior chamber angle development without cell death or macrophage involvement

نویسندگان

  • Beeran Meghpara
  • Xin Li
  • Hiroshi Nakamura
  • Ahsan Khan
  • Bassem A. Bejjani
  • Shan Lin
  • Deepak P. Edward
چکیده

PURPOSE The iridocorneal angle in the mammalian eye including the trabecular meshwork (TM) develops from undifferentiated mesenchyme/neural crest between the iris root and cornea. The precise mechanisms underlying anterior angle development are unclear, and the contribution of cell death and phagocytic resorption by macrophages in angle development is controversial. In this study, we examined the human anterior chamber angle during various stages of development for evidence of cell death and phagocytic resorption. METHODS Eyes from the human fetus (F) of 7, 8, 9, 10, 11, 13, 15, 18, 19, 21, 22, 23, and 27 weeks as well as eyes from 5- and 11-month-old children and donors 24, 48, and 67 years of age were obtained. Formalin-fixed and paraffin-embedded sections were examined by hematoxylin and eosin (H&E) staining. Immunohistochemistry was performed using polyclonal antibodies against CD68. Terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) labeling was also performed to evaluate cell death. RESULTS By light microscopy, the development of human angle structures appeared to progress as previously described. Histological evidence of cellular death or resorption by macrophages was not observed. Furthermore, the chamber angle tissues did not stain with CD68 at any stage of development. Few CD68 positive cells were observed in the iris stroma and the anterior ciliary body between fetal weeks 10 and 18 (F10w and F18w). TUNEL labeled nuclei were not detected in the anterior chamber angle in any fetal or infant eyes. By contrast, TUNEL positive nuclei in TM cells were observed in the examined adult donor specimens. CONCLUSIONS The results suggest that at the time points examined, neither cell death nor phagocytic resorption with macrophages appear to play a role in the development of the human anterior chamber angle.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Apoptosis during macrophage-dependent ocular tissue remodelling.

We have characterized the nature and pattern of cell death during regression of the pupillary membrane, a developmentally transient capillary network found in the anterior chamber of the eye. This analysis has revealed that the cellular components of the pupillary membrane include vascular endothelial cells in an intricate network of fine capillaries as well as attendant macrophages. The capill...

متن کامل

Numerical Analysis of the Thermal Interaction of Cell Phone Radiation with Human Eye Tissues

Introduction: The present study aimed to present a numerical analysis of the penetration depth,  specific absorption rate (SAR), and temperature rise in various eye tissues with varying distance between radiation source and exposed human eye tissues (i.e., cornea, posterior chamber, anterior chamber, lens, sclera, vitreous humor, and iris) at frequencies of 900 and1800 MHz. Materials and Method...

متن کامل

Macrophages induce apoptosis in normal cells in vivo.

It is well established that macrophages have a function in scavenging apoptotic bodies from cells undergoing programmed cell death. Here we show that macrophages can also induce apoptosis of normal cells. Using injected toxic liposomes to eliminate macrophages in the anterior chamber of the rat eye, we provide direct evidence that, in vivo, macrophages induce apoptosis in normal vascular endoth...

متن کامل

Dopamine-Synthesizing Neurons: An Overview of Their Development and Application for Cell Therapy

Cell-gene therapy is a dynamic constituent of novel medical biotechnology. Neurodegenerative disordersin which damage to or demise of specific brain cell types plays central role, are clear examples of diseasecandidate for cell replacement therapy. Dopaminergic (DAergic) neurons biosynthesize dopamine, a vitalneurotransmitter in the central nervous system. Due to the involveme...

متن کامل

Peripheral Anterior Synechiae and Ultrasound Biomicroscopic Parameters in Angle-Closure Glaucoma Suspects

PURPOSE To investigate the correlation between peripheral anterior synechia (PAS) and the quantitative anterior chamber angle parameters measured by ultrasound microscopy (UBM) in angle-closure glaucoma suspect (ACGS) eyes. METHODS Eyes were defined ACGS as having occludable angles and intraocular pressure less than 21 mm Hg without glaucomatous optic nerve head. The gonioscopic criteria for ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2008