Comparison of techniques for the measurement of skin temperature during exercise in a hot, humid environment
نویسندگان
چکیده
Exercising or working in a hot, humid environment can results in the onset of heat-related illness when an individual's temperature is not carefully monitored. The purpose of the present study was to compare three techniques (data loggers, thermal imaging, and wired electrodes) for the measurement of peripheral (bicep) and central (abdominal) skin temperature. Young men and women (N = 30) were recruited to complete the present study. The three skin temperature measurements were made at 0 and every 10-min during 40-min (60% VO2max) of cycling in a hot (39±2°C), humid (45±5% RH) environment. Data was statistically analyzed using the Bland-Altman method and correlation analysis. For abdominal skin temperature, the Bland-Altman limits of agreement indicated that data loggers (1.5) were a better index of wired than was thermal imaging (3.5), For the bicep skin temperature the limits of agreement was similar between data loggers (1.9) and thermal (1.9), suggesting the both were suitable measurements. We also found that when skin temperature exceeded 35°C, we observed progressively better prediction between data loggers, thermal imaging, and wired skin sensors. This report describes the potential for the use of data loggers and thermal imaging to be used as alternative measures of skin temperature in exercising, human subjects.
منابع مشابه
Thermoregulatory, cardiovascular, and perceptual responses to intermittent cooling during exercise in a hot, humid outdoor environment.
Decreasing core body temperature during exercise may improve exercise tolerance, facilitate acclimatization, and prevent heat illness during summer training. We sought to evaluate the effectiveness of intermittent superficial cooling on thermoregulatory, cardiovascular, and perceptual responses during exercise in a hot humid environment. We used a randomized, counterbalanced, repeated measures ...
متن کاملNon-invasive Measures of Core Temperature versus Ingestible Thermistor during Exercise in the Heat
The accuracy of core temperature (Tc) thermometry from temporal, tympanic, and oral thermometry devices has been variable during exercise in a hot, humid environment. The purpose of the present study was to cross-validate temporal, two tympanic devices, and oral devices compared to an ingestible thermistor during exercise in a hot, humid environment. Fourteen young, active adults (6 women) comp...
متن کاملThe Effect of Acute Caffeine Consumption in a Dehydration and Hot and Humid conditions on Aerobic Function, Blood Pressure and Some Factors of the Immune System of Active Men
Background & objectives: Caffeine can affect many physiological functions of the body. The aim of this study was to investigate the response of aerobic function, blood pressure and some immune system factors of trained men to acute caffeine consumption in dehydrated condition and warm and humid environment. Methods: Thirty male athletes with a mean age of 26.6±3.9 years in dehydrated conditions...
متن کاملEffects of acute supplementation of Panax ginseng on endurance running in a hot & humid environment
BACKGROUND & OBJECTIVES Athletes in Malaysia need to perform in a hot and humid environment due to the climatic nature of the country. Chronic supplementation of Panax ginseng (PG) (a deciduous perennial plant belonging to the Araliaceae family) enhances physical performance. As the ergogenic effect of acute supplementation of PG on endurance performance has not been explored in the Malaysian p...
متن کاملExercise in personal protective equipment in a hot, humid environment does not affect risk propensity
We tested the hypothesis that heat stress created by light exertion in encapsulating personal protective equipment (PPE) in a hot, humid environment increases risk propensity. Ten healthy subjects (29 ± 7 y) completed 2 trials presented in a counter-balanced manner. Subjects donned encapsulating PPE, and in one trial they wore a tube-lined shirt underneath that was perfused with 5°C water. Subj...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 32 شماره
صفحات -
تاریخ انتشار 2015