Evaluation of a fluidic ventilator: a new approach to mechanical ventilation.

نویسندگان

  • J R Patterson
  • G K Russell
  • D J Pierson
  • D C Levin
  • L M Nett
  • T L Petty
چکیده

T he emerging technology of fluid amplifiers and control devices has provided a new approach to the design and construction of mechanical ventilators. Fluidics, as this technology has come to be known, has not yet found wide application in medicine, and the fundamentals of fluid control devices are not familiar to many in that field. These are basically simple devices that employ fluids (gases and liquids) to perform operations such as amplification and on and off switching that one might normally associate with electrical devices.lJ As in any amplifier, a large signal is modulated by a small signal. In this instance the power jet of gas is modulated by smaller control jets or switched on and off by being directed from one channel to another by a control jet. The channels through which gas travels are cut into a solid block of suitable material. The fluidic circuit itself contains no moving parts, and potential for mechanical difficulty is reduced accordingly. This technology has found wide and sophisticated application in industrial and space equipment where stability is vital. With mass production and miniaturization techniques, fluidic circuits have become relatively inexpensive. Quite a number of ventilators of various capabilities and description are available here and abroad.3 They are popularly classified as pressure cycled, volume cycled, or time cycled, although they might more accurately be called pressure preset or volume preset machines.' The new device under considemtion (Fig 1) may be either pressure, volume, or time cyded. Inspiratory flow in pressure cycled machines continues until a preset pressure is reached and then terminates. In some machines such as the Bennett PR-1 or 2, inspiration terminates when flow falls to a low tenninal point at the preset pressure. Changes in pulmonary resistance or compliance will alter the volume of gas delivered from pressure cycled ventilators. Therefore, volume cycled ventilators are generally preferred in circumstances requiring continuous mechanical ventilation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Laboratory and clinical evaluation of a new volume ventilator.

A three phase laboratory and clinical evaluation of a new fluidically controlled volume ventilator (Ohio 550) was undertaken to determine if this more compact, less complex and less costly unit retained the multiple advantages which have been established for volume ventilators in the continuous ventilatory support of patients in respiratory failure. Inspired volume, peak pressure, and flow rate...

متن کامل

Evaluation of Troponin-T level in Neonate with Mechanical Ventilation

Introduction: Troponin- T is the best biological marker of heart injuries, that isn’t affected by sex, age, birth weight and gestational age. Myocardial damage in infancy is a risk factor eventual cardiac disease. This study carried out for cardiac evaluation of neonates with mechanical ventilation by Troponin T. Methods: This case-control study carried out on 60 infants that were admitte...

متن کامل

Comparison of the effect of pressure support ventilation and volume assured pressure support ventilation on weaning patients off mechanical ventilation after cardiac surgery

Background: Weaning from mechanical ventilation in the intensive care unit is an important step in the treatment process. More patients in less than 6 hours after cardiac surgery can be separated from mechanical ventilation and extubated. However, 20-40% of patients after cardiac surgery, due to dysfunctional ventilator weaning response (DVWR), still remain under mechanical ventilation. Therefo...

متن کامل

Review Paper: The Bed Incline and Prevention of Ventilator-Associated Pneumonia

Background: Ventilator-Associated Pneumonia (VAP) is the most common nosocomial (hospital acquired) infection among patients undergoing mechanical ventilation. It increases mortality rate, duration of mechanical intubated ventilation, and hospitalization in the Intensive Care Units (ICUs). This review study aims to determine the proper gradient of a hospital bed in preventing VAP in patients ho...

متن کامل

Evaluation of the Effects of Oronasal Versus Oral Disinfections with Chlorhexidine on Clinical Criteria of Ventilator-associated Pneumonia

Background: Ventilator-associated pneumonia (VAP) is the most prevalent and lethal form of nosocomial infections in the ICU and oral disinfection is a nursing measure to prevent this condition. Aim: this study aimed to evaluate the effect of oronasal versus oral disinfections with chlorhexidine on the clinical criteria for diagnosis of VAP. Method: This randomized clinical trial was conducted o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Chest

دوره 66 6  شماره 

صفحات  -

تاریخ انتشار 1974