Fetal dose conversion factor for fetal computed tomography examinations: A mathematical phantom study

نویسندگان

  • Yuta Matsunaga
  • Ai Kawaguchi
  • Masanao Kobayashi
  • Shoichi Suzuki
  • Yasuki Asada
  • Kiyoshi Ito
  • Koichi Chida
چکیده

This study aimed to examine the relationship between fetal dose and the dose-length product, and to evaluate the impact of the number of rotations on the fetal doses and maternal effective doses using a 320-row multidetector computed tomography unit in a wide-volume mode. The radiation doses for the pregnant woman and the fetus were estimated using ImPACT CT Patient Dosimetry Calculator software for scan lengths ranging from 176 to 352 mm, using a 320-row unit in a wide-volume mode and an 80-row unit in a helical scanning mode. In the 320-row unit, the fetal doses in all scan lengths ranged from 3.51 to 6.52 mGy; the maternal effective doses in all scan lengths ranged from 1.05 to 2.35 mSv. In the 80-row unit, the fetal doses in all scan lengths ranged from 2.50 to 3.30 mGy; the maternal effective doses in all scan lengths ranged from 0.83 to 1.68 mSv. The estimated conversion factors from the dose-length product (mGy・cm) to fetal doses (mGy) for the 320-row unit in wide-volume mode and the 80-row unit in helical scanning mode were 0.06 and 0.05 (cm-1 ) respectively. While using a 320-row MDCT unit in a wide-volume mode, operators must take into account the number of rotations, the beam width as automatically determined by the scanner, the placement of overlap between volumetric sections, and the ratio of overlapping volumetric sections.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Phantom Size and Tube Voltage on the Size-Conversion Factor for Patient Dose Estimation in Computed Tomography Examinations

Introduction: This study aimed to establish the conversion factors to normalize the output dose of volumetric computed tomography dose index (CTDIvol) to the patient dose (i.e. size-specific dose estimate (SSDE)) for various phantom diameters and tube voltages. Material and Methods: In-house cylindrical acrylic phantoms with physical diameter...

متن کامل

Radiation Doses to the Unborn Child at Diagnostic Examinations in Sweden

This report describes methods to estimate fetal radiation doses from radiation diagnostic examinations, based on survey data from 3 hospitals in southern Sweden. The fetal dose has been calculated with available computer programs and verified by dose measurements inside a female human phantom for conventional X-ray and computed tomography (CT) examinations. Measured fetal doses have been correl...

متن کامل

Diagnostic Reference Levels for Computed Tomography Examinations in Iran: A Nationwide Radiation Dose Survey

Introduction: International Commission on Radiological Protection introduced three basic principles of radiation protection, namely justification, optimization, and dose limit. Medical exposure has no dose limits, and generally, diagnostic reference levels are used as a tool for optimization of patient protection. Material and Methods: Dosimetry was performed on 20 CT scanners located in 14 cit...

متن کامل

Organ Dose Determination in X-ray Imaging

Organ dose is the absorbed radiation energy from ionizing radiation to an organ, divided by the organ mass. Organ doses of a patient cannot be measured directly in the patient, but their determination requires dose measurements in anthropomorphic patient models i.e. phantoms or Monte Carlo simulations. Monte Carlo simulations can be performed for example by using computational phantoms or patie...

متن کامل

Thorax organ dose estimation in computed tomography based on patient CT data using Monte Carlo simulation

Background:  This study presents patient specific and organ dose estimation in computed tomography (CT) imaging of thorax directly from patient CT image using Monte Carlo simulation.  Patient's CT image is considered as the patient specific phantom and the best representative of patient physical index in order to calculate specific organ dose. Materials and Methods: EGSnrc /BEAMnr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2017