Novel Handheld Magnetometer Probe Based on Magnetic Tunnelling Junction Sensors for Intraoperative Sentinel Lymph Node Identification

نویسندگان

  • A. Cousins
  • G. L. Balalis
  • S. K. Thompson
  • D. Forero Morales
  • A. Mohtar
  • A. B. Wedding
  • B. Thierry
چکیده

Using magnetic tunnelling junction sensors, a novel magnetometer probe for the identification of the sentinel lymph node using magnetic tracers was developed. Probe performance was characterised in vitro and validated in a preclinical swine model. Compared to conventional gamma probes, the magnetometer probe showed excellent spatial resolution of 4.0 mm, and the potential to detect as few as 5 μg of magnetic tracer. Due to the high sensitivity of the magnetometer, all first-tier nodes were identified in the preclinical experiments, and there were no instances of false positive or false negative detection. Furthermore, these preliminary data encourage the application of the magnetometer probe for use in more complex lymphatic environments, such as in gastrointestinal cancers, where the sentinel node is often in close proximity to other non-sentinel nodes, and high spatial resolution detection is required.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sentinel Node Mapping in Non-small Cell Lung Cancer Using an Intraoperative Radiotracer Technique

 Objective(s): Lymph node metastases are the most significant prognostic factor in localized non-small cell lung cancer (NSCLC). Identification of the first nodal drainage site (sentinel node) may improve detection of metastatic nodes. Extended surgeries, such as lobectomy or pneumonectomy with lymph node dissection, are among the therapeutic options of higher acceptab...

متن کامل

Feasibility of sentinel lymph node mapping in renal cell carcinoma using intraoperative radiotracer injection

Introduction: The applicability of sentinel lymph node biopsy for early detection of metastasis in patients with renal cell carcinoma (RCC) is still in the validation phase and under investigation, which might be due to the unpredictability of the lymphatic pattern in RCC. In this study, we aimed to evaluate the feasibility and accuracy of sentinel node biopsy in patients with ...

متن کامل

Comparison of three magnetic nanoparticle tracers for sentinel lymph node biopsy in an in vivo porcine model

INTRODUCTION Breast cancer staging with sentinel lymph node biopsy relies on the use of radioisotopes, which limits the availability of the procedure worldwide. The use of a magnetic nanoparticle tracer and a handheld magnetometer provides a radiation-free alternative, which was recently evaluated in two clinical trials. The hydrodynamic particle size of the used magnetic tracer differs substan...

متن کامل

Monte Carlo-based optimization of a gamma probe system for sentinel lymph node mapping

Introduction: Sentinel lymph node biopsy (SLNB) is a standard surgical technique to identify sentinel lymph node (SLN) for the staging of early breast cancer. Nowadays, two methods are used for the identification of SLN: blue dye method aiding visually and radioactive dye using gamma detector. A wide range of gamma probe systems with different design and performance are used in...

متن کامل

Feasibility of intraoperative detection of sentinel lymph nodes with 89-zirconium-labelled nanocolloidal albumin PET-CT and a handheld high-energy gamma probe

BACKGROUND PET/CT lymphoscintigraphy using 89Zr-nanocolloidal albumin has the potential to improve the preoperative identification of sentinel lymph nodes (SLNs), especially if located in the near proximity of the primary tumour. This study aims to demonstrate the feasibility of PET/CT lymphoscintigraphy followed by intraoperative detection of 89Zr-nanocolloidal albumin containing SLNs with the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2015