Determination of blood flow to the transplanted kidney. A novel application of phase-contrast, cine magnetic resonance imaging.

نویسندگان

  • B D Myers
  • F G Sommer
  • K Li
  • S Tomlanovich
  • N Pelc
  • C McDonnell
  • E Pagtalunan
  • L Newton
  • R Jamison
چکیده

There is at present no noninvasive method that reliably measures blood flow in the poorly functioning renal allograft. The present study was designed to evaluate phase-contrast cine magnetic resonance imaging (PC-cine-MRI) for this purpose. We recruited for study 18 patients who had received kidney transplants 13-66 months earlier from closely related living donors. As judged by the glomerular filtration rate, which was elevated for a single kidney (76 +/- 4 ml/min 1.73 m2), allograft function was excellent, permitting the assumption of unimpaired renal extraction of paminohippuric acid (PAH). Allograft blood flow was determined consecutively on the same day, first by the standard PAH clearance technique and they by the product of the velocity of protons and renal vein cross-sectional area using PC-cine-MRI. MRI determinations could not be completed because of claustrophobia in two patients and failure to image the terminus of the allograft vein another two. Comparison of blood flow in the remaining 14 subjects revealed the two techniques to be strongly related (r = 0.91, P < 0.001). On the average, the renal blood flow rate was similar by each method; 732 +/- 62 by PAH clearance and 703 +/- 69 ml/min by PC-cine-MRI, but the agreement among individuals between the two methods was only modest, with a 95% confidence interval of agreement from -214 to +254 ml/min. We conclude that PC-cine-MRI provides a fairly accurate and noninvasive method for determining the rate of blood flow in the transplanted kidney. With further refinement it should permit the role of depressed blood flow in a variety of acute and chronic forms of human allograft dysfunction to be elucidated in humans for the first time.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Synthesis and biological evaluation of a novel Glucosylated Derivative of Gadolinium Diethylenetriaminepentaacetic acid for Tumor Magnetic Resonance Imaging

Cancer detection in early stage using a powerful and noninvasive tool is of high global interest. In this experiment, a small-molecular-weight glucose based derivative of Gd3+-1-(4-isothiocyanatobenzyl) diethylene tri amine penta acetic acid (Gd3+-p-SCN-Bn‐DTPA‐DG) as a novel potential MR imaging contrast agents was synthesized. Gd3+-p-SCN-Bn‐DTPA‐DG was synthesized with reacting of Glucosamine...

متن کامل

Peak flow velocities in the ascending aorta-real-time phase-contrast magnetic resonance imaging vs. cine magnetic resonance imaging and echocardiography.

This prospective study of eight healthy volunteers evaluates peak flow velocities (PFV) in the ascending aorta using real-time phase-contrast magnetic resonance imaging (MRI) in comparison to cine phase-contrast MRI and echocardiography. Flow measurements by echocardiography and cine phase-contrast MRI with breath-holding were performed according to clinical standards. Real-time phase-contrast ...

متن کامل

Dynamic Contrast Magnetic Resonance Imaging (DCE-MRI) and Diffusion Weighted MR Imaging (DWI) for Differentiation between Benign and Malignant Salivary Gland Tumors

Background: Salivary gland tumors form nearly 3% of head and neck tumors. Due to their large histological variety and vicinity to facial nerves, pre-operative diagnosis and differentiation of benign and malignant parotid tumors are a major challenge for radiologists. Objective: The majority of these tumors are benign; however, sometimes they tend to transform into a malignant form. Functional M...

متن کامل

Real-time flow MRI of the aorta at a resolution of 40 msec.

PURPOSE To evaluate a novel real-time phase-contrast magnetic resonance imaging (MRI) technique for the assessment of through-plane flow in the ascending aorta. MATERIALS AND METHODS Real-time MRI was based on a radial fast low-angle shot (FLASH) sequence with about 30-fold undersampling and image reconstruction by regularized nonlinear inversion. Phase-contrast maps were obtained from two (i...

متن کامل

Application of phase-contrast cine magnetic resonance imaging in endoscopic aqueductoplasty

The aim of this study was to evaluate the application of phase-contrast cine magnetic resonance imaging (MRI) in endoscopic aqueductoplasty (EA) for patients with obstructive hydrocephalus. The clinical diagnosis of hydrocephalus caused by aqueduct obstruction in 23 patients was confirmed by phase-contrast cine MRI examination. The patients were treated with EA and MRI was repeated during the f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Transplantation

دوره 57 10  شماره 

صفحات  -

تاریخ انتشار 1994