Analytical performance of a portable critical care blood gas analyzer.
نویسندگان
چکیده
The portable blood gas analyzer OPTI Critical Care Analyzer was evaluated in comparison to routine laboratory assays using heparinized blood samples of adults and newborns. Within-run imprecision studies were performed with native blood using tonometry to adjust blood gas concentrations. The results obtained show a very close agreement between the OPTI system and the comparison methods for all parameters tested: hemoglobin (y=1.00x-0.2 g/l, r=0.997, n=81), sodium (y=1.13x-18.7 mmol/l, r=0.951, n=79), potassium (y=1.03x-0.04 mmol/l, r=0.972, n=79), pH (y=1.03x-0.29, r=0.958, n=57), pCO2 (y=1.03x-1.14 mm Hg, r=0.988, n=57) and pO2 (y=1.07x-0.85 mm Hg, r=0.995, n=57). The coefficients of variation for the within-run imprecision were below 1.1% for sodium and hemoglobin, and below 2.6% for all other parameters, except for pCO(2) with coefficients of variation up to 3.6% at low calibration gas concentrations. Due to this analytical performance and its portability, the OPTI system is well suited for low to medium test frequencies and immediate use in emergency rooms, intensive care or surgery units.
منابع مشابه
Evaluation of the i-STAT Portable Clinical Analyzer for point-of-care blood testing in the intensive care units of a university children's hospital.
We evaluated the analytical performance of the i-STAT Portable Clinical Analyzer (PCA), a point-of-care testing system consisting of a hand-held analyzer and single-use cartridges that measure different panels of electrolytes, metabolites, blood gases, and hematocrit in 65-100 microl of blood. Our objective was to determine whether PCA measurements at the bedside of patients in the neonatal and...
متن کاملEvaluation of the i-STAT portable clinical analyzer in chickens (Gallus gallus).
The i-STAT portable clinical analyzer (PCA) was evaluated for performance in avian species. With the EG7+ cartridge, which provided results for hydrogen ion concentration, oxygen tension, carbon dioxide tension, sodium, potassium, ionized calcium, hematocrit, and various calculated parameters, analytical accuracy and precision were tested by comparing obtained values to those of established tra...
متن کاملAnalytical evaluation of i-STAT Portable Clinical Analyzer and use by nonlaboratory health-care professionals.
We evaluated the performance of the i-STAT Portable Clinical Analyzer, a hand-held instrument that, with its current cartridge, analyzes for electrolytes, urea nitrogen, glucose, and hematocrit in approximately 60 microL of whole blood in approximately 90 s. Accuracy, imprecision, and linearity studies were performed with aqueous controls and standards and by split-sample analysis. Intrarun imp...
متن کاملPortable blood gas and electrolyte analyzer evaluated in a multiinstitutional study.
A recently introduced blood gas/electrolyte analyzer (SenDx 100((R)), renamed ABL70) intended for point-of-care, near-patient, or stat laboratory use was evaluated simultaneously in four different institutions and compared with three different laboratory bench analyzers with respect to imprecision, inaccuracy (assessed by tonometry), and patient-sample analyses. The analyzer is equipped with a ...
متن کاملUse of a rapid arterial blood gas analyzer to estimate blood hemoglobin concentration among critically ill adults
OBJECTIVE To evaluate whether measurement of the hemoglobin (Hb) concentration with a blood gas analyzer approximates that determined by a conventional coulter counter in critically ill adults. DESIGN Prospective patient series. SETTING A 32-bed cardiovascular, neurosurgical, trauma and medical-surgical intensive care unit in a single Canadian center. PATIENTS We consecutively recruited 2...