Comparative computational fluid dynamic study of two distal Contegra conduit anastomoses.

نویسندگان

  • Antonio F Corno
  • Elizabeth S Mickaily-Huber
چکیده

A computational fluid dynamic (CFD) study compared two configurations of distal anastomosis of 12 mm Contegra conduit: conventional 'circular' vs. oblique 'elliptical' anastomosis extended on the left PA, evaluating pressure and velocity profiles, and shear stress, from PA origin to the bifurcation. 'Elliptical' anastomosis provides larger (=54% difference) cross-sectional area than 'circular' anastomosis. Velocity contours showed important stagnation at PA bifurcation in 'circular' anastomosis and minimal in 'elliptical' configuration, where fluid flow occurred preferentially in left PA. Pressure contours showed peak pressure zone at bifurcation in 'circular' anastomosis, while 'elliptical' exhibited more uniform pressure distribution. Shear stress distribution was more homogeneous in 'elliptical' than in 'circular' anastomosis. At bifurcation and in right PA artery velocity and pressure were higher for 'circular' than 'elliptical' anastomosis, while in left PA velocity was much higher for 'elliptical' anastomosis. CFD study demonstrates more homogeneous pressure, velocity and shear stress distributions for 'elliptical' compared to 'circular' anastomosis at PA bifurcation, and preferential flow in left PA. CFD results suggest that clinical application of 'elliptical' anastomosis, with cross-sectional area larger than conventional 'circular' anastomosis, may reduce incidence and degree of distal stenosis, particularly for small size conduits.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contegra valved conduit in the paediatric population: an exciting prospect for right ventricle to pulmonary artery reconstruction; experience and outcomes at Aga Khan University.

OBJECTIVE The focus of this study is to share the experience and outcomes of Contegra graft implantation in the paediatric and adult population in Pakistan. METHODS Between May 2007 and July 2011, 16 patients, underwent implantation of a Contegra valved conduit. All operations were performed through a median sternotomy with cardiopulmonary bypass. Indications included: Pulmonary atresia with ...

متن کامل

The Contegra valved bovine conduit: a biomaterial for the surgical treatment of congenital heart defects.

Contegra, a bovine jugular vein graft, has been widely used as a preferable biomaterial in the surgical treatment of congenital heart defects, especially as a conduit for the right ventricular outflow tract reconstruction. This article aims to make a comprehensive review on the clinical outcomes of Contegra. Reports of Contegra published since 2002 were comprehensively retrieved, collected and ...

متن کامل

Contegra conduit anastomoses

30 ‘circular’ vs. oblique ‘elliptical’ anastomosis extended on the left PA, evaluating pressure and velocity profiles, and shear stress, from PA 31 origin to the bifurcation. ‘Elliptical’ anastomosis provides larger (s54% difference) cross-sectional area than ‘circular’ anastomosis. Velocity 32 contours showed important stagnation at PA bifurcation in ‘circular’ anastomosis and minimal in ‘elli...

متن کامل

Midterm results of bovine jugular vein conduit for right ventricular outflow tract reconstruction.

OBJECTIVE To evaluate the midterm results of Contegra conduit. METHODS The retrospective study comprised patient record at Aga Khan University Hospital, Karachi, of conduits implanted between May 2007 and June 2012. Data collection was made from the clinical notes and from serial echocardiograms by a single cardiologist. The last followup echocardiography was done at the time of data collecti...

متن کامل

Analysis of Computational Fluid Dynamics and Particle Image Velocimetry Models of Distal-End Side-to-Side and End-to-Side Anastomoses for Coronary Artery Bypass Grafting in a Pulsatile Flow.

BACKGROUND Intimal hyperplasia (IH) is a major cause of graft failure. Hemodynamic factors such as stagnation and disturbed blood flow are involved in IH formation. The aim of this study is to perform a comparative analysis of distal-end side-to-side (deSTS) and end-to-side (ETS) anastomoses using computational fluid dynamics (CFD) after validating the results via particle image velocimetry (PI...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Interactive cardiovascular and thoracic surgery

دوره 7 1  شماره 

صفحات  -

تاریخ انتشار 2008