Common Mode Problematic of Solar Inverter Systems
نویسنده
چکیده
In the medium and high power range (starting from about 5kW) mostly three-phase Solar inverter systems are used. The PWM-systems reduce the harmonics of the mains current but insert a high frequency voltage between the DC-link and the neutral point of the AC-side, which is called common mode disturbance voltage here. This voltage is shown to be a four-level signal whose amplitude is in the range of the DC-link voltage. Its frequency is at least switching frequency and its rate of rise depends on the switching speed of the power semiconductors used. The required switching frequency for low distortion input currents and the resulting switching speed of modern semiconductors lead to excessive earth currents. Especially big solar fields show a considerable ground (earth) capacitance leading to problematic leakage current in DC-slink side. Both countermeasures, the reduction and the short connection of the parasitic earth capacitances (as well as the insertion of a differential inductor in both cases) lead to non trivial resonance problems. The problems are described in detail and a solution is proposed. Key-Words: Common Mode Disturbances , Solar Inverter, PWM Inverter
منابع مشابه
Single phase pv inverter pdf
A proprietary data monitoring receiver has been integrated into the single phase solar inverter and aggregates the power optimizer performance data from each. single phase solar inverter price A single-phase grid connected transformerless photovoltaic PV inverter for. ABSTRACT In this paper the issue of control strategies for single-stage photovoltaic PV inverter is addressed. single phase pv i...
متن کاملEvaluation of Single Phase Transformerless Photovoltaic Inverters
Transormerless inverters are attractive solution for the grid connected photovoltaic (PV) systems. Unfortunately, it has issues on galvanic isolation between PV systems to the grid. When the galvanic isolation disappears from the PV inverter, leakage currents will flow in a resonant circuit formed by the ground capacitance, the converter, the ac filter and the grid. In order to avoid the leakag...
متن کاملAn efficient Grid tie Solar PV based Single Phase Transformer less Inverter on common mode voltage analysis
The paper presents common mode voltage analysis of single phase grid connected photovoltaic inverter. Many researchers proposed different grid tie inverters for applications like domestic powering, street lighting, water pumping, cooling and heating applications. Traditional grid tie PV inverter uses either a line frequency or a high frequency transformer between the inverter and grid. The tran...
متن کاملSpace Vector Pulse Width Modulation with Reduced Common Mode Voltage and Current Losses for Six-Phase Induction Motor Drive with Three-Level Inverter
Common-mode voltage (CMV) generated by the inverter causes motor bearing failures in multiphase drives.On the other hand, presence of undesired z-component currents in six-phase induction machine (SPIM) leads to extra current losses and have to be considered in pulse width modulation (PWM) techniques. In this paper, it is shown that the presence of z-component currents and CMV in six phase driv...
متن کاملA Transformer-less Inverter with Reduced Common Mode Leakage Current for Pv Applications
The DC/AC inverters are used in grid-coupled Photovoltaic (PV) energy fabrication systems as the power meting out interface between the PV power source and the electric grid. Compared to the grid-coupled PV inverters that have galvanic separation (either on the DC, or on the AC side),the transformer-less PV inverters have the advantages of lower cost, higher efficiency, smaller size and lower w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -