A direct radioimmunoassay for aldosterone in unextracted serum and plasma.

نویسندگان

  • T P Lee
  • C H Tan
چکیده

We describe a novel radioimmunoassay procedure for the direct estimation of aldosterone in unextracted plasma and serum samples, in which interfering binding proteins are digested by Proteinase K (Tritirachium alkaline proteinase, EC 3.4.21.14), a powerful proteolytic enzyme. Heating at 75 degrees C for 15 min inactivates the enzyme before radioimmunoassay. Alternatively, EDTA may be used to inactivate the enzyme. The antibody-bound fraction is then precipitated with polyethylene glycol and isolated by centrifugation. This easy method eliminates extraction and purification and gives accurate and reliable results. The total time required for 100 estimations, including counting time, is about 6 h.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Solid-phase chemiluminescence immunoassay for progesterone in unextracted serum.

We describe a simple, solid-phase chemiluminescence immunoassay for progesterone in 10 microL of unextracted serum ("direct" assay). Danazol at pH 8.0 is included (100 ng per tube) to displace progesterone from binding proteins in serum. A progesterone-11 alpha-hemisuccinyl-aminobutylethyl isoluminol conjugate serves as the chemiluminescent ligand marker and homologous antiprogesterone IgG cova...

متن کامل

A simplified radioimmunoassay of plasma aldosterone.

The analytical evaluation is described of a [125I]-aldosterone radioimmunoassay method for measuring aldosterone in human plasma, which requires no chromatographic purification before quantification by radioimmunoassay but does require organic solvent extraction. Rabbit anti-aldosterone serum is used, generated against aldosterone-3-oxime coupled to thyroglobulin. The antibody demonstrates negl...

متن کامل

Low somatomedin-C (Sm-C) concentrations measured by direct radioimmunoassay in patients with chronic renal failure.

Ten patients suffering from chronic renal failure and undergoing regular hemodialysis were tested immediately before and immediately after a 3-hour dialysis. Serum levels of immunoreactive Sm-C, estimated on unextracted non acidified serum at non equilibrium, were significantly lower than in normal controls and no consistent modifications were observed after dialysis.

متن کامل

Radioimmunoassay for mono-(2-ethylhexyl) phthalate in unextracted plasma.

We report a radioimmunoassay for mono-(2-ethylhexyl) phthalate that has been coupled to a protein carrier as a radioligand. Competitive interference tests with a variety of related compounds indicated the assay to be highly specific. Quantitative comparison of mono-(2-ethylhexyl) phthalate values in plasma and serum samples between the radioimmunoassay and gas chromatographic procedures indicat...

متن کامل

Direct measurement of testosterone in a pediatric center, with use of a radioimmunoassay kit and unextracted serum.

We evaluated a commercial (Radioassay Systems) radioimmunoassay kit for testosterone in which a double-antibody method and an 125I tracer are used. The 50-microL serum sample is assayed directly with no pre-extraction step. The assay system has good sensitivity (0.01 microgram/L), good precision (CV 5.2%), and little cross reactivity between testosterone and other androgens. Results compared we...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 27 12  شماره 

صفحات  -

تاریخ انتشار 1981