Diagnostic accuracy of 1.5-T unenhanced whole-heart coronary MR angiography performed with 32-channel cardiac coils: initial single-center experience.

نویسندگان

  • Motonori Nagata
  • Shingo Kato
  • Kakuya Kitagawa
  • Nanaka Ishida
  • Hiroshi Nakajima
  • Shiro Nakamori
  • Masaki Ishida
  • Masatoshi Miyahara
  • Masaaki Ito
  • Hajime Sakuma
چکیده

PURPOSE To compare the imaging time and image quality obtained with whole-heart coronary magnetic resonance (MR) angiography performed with five- and 32-channel coils in healthy subjects and determine the accuracy of MR angiography performed with 32-channel coils in the detection of obstructive coronary artery disease (CAD). MATERIALS AND METHODS The institutional review board approved the study protocol, and all participants provided written informed consent. The authors studied 10 healthy subjects and 67 patients suspected of having CAD who were scheduled for coronary angiography. Unenhanced 1.5-T coronary MR angiography was performed with five- and 32-channel coils in healthy subjects and with 32-channel coils in patients. Clinically significant CAD was defined as a diameter reduction of at least 50% at coronary angiography. The sensitivity and specificity of coronary MR angiography were calculated. RESULTS The mean imaging time was substantially reduced from 12.3 minutes ± 4.2 (standard deviation) with five-channel coils to 6.3 minutes ± 2.2 with 32-channel coils, with equivalent image quality scores. Acquisition of MR angiograms was completed in all 67 patients, with a mean imaging time of 6.2 minutes ± 2.8. The prevalence of CAD in the study population was 58% (39 of the 67 patients). The areas under the receiver operating characteristic curves as determined at vessel- and patient-based analyses were 0.91 and 0.90, respectively; the sensitivity and specificity at vessel-based analysis were 86% and 93%, respectively. CONCLUSION Whole-heart coronary MR angiography performed at 1.5 T with 32-channel coils permits noninvasive detection of CAD with substantially reduced imaging time. This noninvasive approach can be an alternative to multidetector computed tomographic coronary angiography for ruling out obstructive CAD in patients who have a contraindication to contrast material and in young subjects who are at higher risk from ionizing radiation. SUPPLEMENTAL MATERIAL http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11101323/-/DC1.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3.0T Whole-Heart Coronary Magnetic Resonance Angiography Performed with 32-Channal Cardiac Coils: A Single Center Experience Yang et al: 3T Whole-Heart Coronary MR Angiography with 32-Channel Coils

Departments of Radiology, Xuanwu Hospital, Capital Medical University, Beijing, China Institute of Biomedical and Health Engineering, Shenzhen Institute of Advanced Technology Chinese Academy of Sciences, Shenzhen, China Siemens Healthcare, Chicago, IL Advanced Concept Development, Invivo Corporation, Gainesville, FL Siemens Healthcare, MR Collaboration NE Asia, Shanghai, China Imaging Institut...

متن کامل

3.0T whole-heart coronary magnetic resonance angiography performed with 32-channel cardiac coils: a single-center experience.

BACKGROUND Whole-heart coronary magnetic resonance angiography (MRA) is a promising method for noninvasive, radiation-free detection and exclusion of obstructive coronary artery disease; however, the required imaging time and robustness of the technique are not yet satisfactory. We evaluated the value of whole-heart coronary MRA at 3.0T using a 32-channel cardiac coil, which reduces image-acqui...

متن کامل

3T Contrast-Enhanced Whole Heart Coronary MRA using 32-Channel Cardiac Coils for the Detection of Coronary Artery Disease

Introduction: The development of contrast enhanced whole heart coronary MR angiography (CMRA) at 3T has shown promising results in clinical studies for the detection of significant coronary artery stenoses. However, the imaging time (~ 9 minutes) and spatial resolution (1.3 × 1.3 × 1.3 mm) remain major limitations. Newly available 32-channel cardiac coils allow greater acceleration factors, and...

متن کامل

Diagnostic Accuracy of Different Image Postprocessing Methods for the Detection of Coronary Artery Stenoses by Using Contrast Enhanced Coronary MRA at 3.0T

Introduction: Contrast enhanced 3T whole heart coronary MR angiography (CMRA) is a reliable method for the detection and exclusion of hemodynamically significant coronary stenosis and has shown high accuracy in recent single center trial. Whole heart coronary MR angiography has been introduced as a method that can provide visualization of long segments of all coronary arteries with a single 3D ...

متن کامل

3D Whole-Heart Coronary MR Angiography at 1.5T in Healthy Volunteers: Comparison between Unenhanced SSFP and Gd-Enhanced FLASH Sequences

OBJECTIVE To validate the optimal cardiac phase and appropriate acquisition window for three-dimensional (3D) whole-heart coronary magnetic resonance angiography (MRA) with a steady-state free precession (SSFP) sequence, and to compare image quality between SSFP and Gd-enhanced fast low-angle shot (FLASH) MR techniques at 1.5 Tesla (T). MATERIALS AND METHODS Thirty healthy volunteers (M:F = 2...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiology

دوره 259 2  شماره 

صفحات  -

تاریخ انتشار 2011