[In-phase and out-of-phase single-shot magnetization-prepared gradient recalled echo: description and optimization of technique at 1.5 T].

نویسندگان

  • M Ramalho
  • V Herédia
  • R O P de Campos
  • M de Toni
  • B M Dale
  • R C Semelka
چکیده

PURPOSE To implement in-phase and out-of-phase (IP/OP) techniques with Magnetization-Prepared Gradient Recalled Echo (MP-GRE) and to evaluate the feasibility and diagnostic image quality among pre and post-optimized MP-GRE sequences, including patients unable to cooperate with breath-hold requirements. MATERIALS AND METHODS Institutional review board approval with waiver of informed consent was obtained for this HIPAA-compliant retrospective study. Two groups of patients were included in the study, before and after optimization of MP-GRE parameters, with seventy-three (24 noncooperative/49 cooperative) and sixty-four (22 noncooperative/42 cooperative) consecutive patients, respectively. The motion-insensitive sequence used in this study was a single-shot 2D MP-GRE. Two radiologists qualitatively evaluated the sequences to identify the presence of phase cancellation artifact in OP images and to determine image quality, extent of artifacts (respiratory ghosting, bounce-point artifact, spatial misregistration and pixel graininess) and lesion conspicuity on the various sequences. The ability to visually detect liver steatosis and fatty adrenal adenomas was evaluated. Qualitative analyses were compared using the Wilcoxon and Mann-Whitney tests. RESULTS There were statistically significant differences between all MP-GRE sequences concerning phase cancellation artifact (P<.0001) which was present in MP-GRE OP sequences and negligible to absent in the pre (IP1) and post-optimized (IP2) MP-GRE IP sequences, respectively, in all patients. Bounce point artifacts were significantly more pronounced in MP-GRE IP1 (P<.0001). Spatial misregistration was slightly more prominent in noncooperative patients with MP-GRE IP2 (P=.0027). MP-GRE OP and MP-GRE IP2 showed significantly higher overall image quality (P<.0001). MP-GRE sequences subjectively identified hepatic steatosis (n=20) and adrenal adenomas (n=5) based on signal loss from IP to OP sequence. CONCLUSION Single shot IP/OP MP-GRE is feasible and allows motion resistant imaging with adequate diagnostic image quality. This technique is able to provide IP and OP information in patients unable to suspend respiration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Magnetization-Prepared Shells With Integrated RadiaL and Spirals

Introduction 3D magnetization-prepared fast gradient echo MR sequences, such as MP-RAGE [1], have been widely used for 3D brain volumetric imaging due to high spatial resolution and good contrast between white matter and gray matter. However, these techniques usually require long acquisition time, which increases the probability of motion and decreases clinical throughput. There have been sever...

متن کامل

Effect of Phase-Encoding Reduction on Geometric Distortion and BOLD Signal Changes in fMRI

Introduction Echo-planar imaging (EPI) is a group of fast data acquisition methods commonly used in fMRI studies. It acquires multiple image lines in k-space after a single excitation, which leads to a very short scan time. A well-known problem with EPI is that it is more sensitive to distortions due to the used encoding scheme. Source of distortion is inhomogeneity in the static B0 field that ...

متن کامل

MR imaging of joints: analytic optimization of GRE techniques at 1.5 T.

To clarify the choice of imaging parameters for optimal gradient-recalled echo MR scanning of joints, we analyzed the behavior of contrast-to-noise and signal-to-noise ratios for spoiled (i.e., fast low-angle shot [FLASH] or spoiled GRASS) and steady-state (i.e., gradient-recalled acquisition in the steady state [GRASS] or fast imaging with steady precession) techniques at 1.5 T. The analysis i...

متن کامل

New Imaging Strategies Using a Motion-Resistant Liver Sequence in Uncooperative Patients

MR imaging has unique benefits for evaluating the liver because of its high-resolution capability and ability to permit detailed assessment of anatomic lesions. In uncooperative patients, motion artifacts can impair the image quality and lead to the loss of diagnostic information. In this setting, the recent advances in motion-resistant liver MR techniques, including faster imaging protocols (e...

متن کامل

Alternative T1-weighted In-phase/Out-of-phase Imaging For Body MRI at 3T

A. T. Vu, V. M. Mai, P. V. Prasad, R. R. Edelman Evanston Northwestern Healthcare, Feinberg School of Medicine, Northwestern Univeristy, Evanston, IL, United States Synopsis An alternative T1-weighted fat/water in-phase/out-of-phase gradient echo imaging pulse sequence is proposed for routine body MRI at 3T. The pulse sequence provides T1 weighting using single shot inversion recovery preparati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiologia

دوره 56 2  شماره 

صفحات  -

تاریخ انتشار 2014