Contributions of femoral fixation methods to the stiffness of anterior cruciate ligament replacements at implantation.

نویسندگان

  • J T To
  • S M Howell
  • M L Hull
چکیده

One purpose of this study was to determine the stiffness of three femoral fixation methods used commonly in anterior cruciate ligament (ACL) reconstruction to secure a double-looped semitendinosus and gracilis (DLSTG) graft and then assess how the stiffness of these methods affects the stiffness of the young human femur-fixation method-graft complex at the time of reconstruction. A second purpose was to define principles for adjusting the stiffness of the ACL replacement (defined as the femoral fixation method plus DLSTG graft plus tibial fixation method) to match that of the native ACL. The stiffness of a DLSTG graft and the stiffness of the femur-fixation method-DLSTG graft complex for three endoscopic fixation methods were measured. Fixations of the DLSTG graft to a button, anchor, and post, both with and without compaction of bone, were tested in young, human femur. The stiffness of each fixation was calculated by modeling the DLSTG graft and fixation method as a series of springs. The stiffness of the DLSTG graft averaged 954+/-292 N/mm. The stiffness of the DLSTG graft-fixation complex was lowered fourfold to 40-fold by adding fixation. The method of fixation determined the reduction in stiffness. The stiffness of the femur-button-DLSTG graft complex averaged 23+/-2 N/mm, the femur-anchor-DLSTG graft complex averaged 25+/-3 N/mm, and the femur-post with bone graft-DLSTG graft complex averaged 225+/-23 N/mm (P = .0001). The knot in the suture loop was the least stiff component and determined the stiffness when the DLSTG graft was fixed with both the button and anchor. Compaction of bone significantly increased stiffness by an average of 41+/-14 N/mm (P = .027). Because the stiffness of femoral fixation methods are 4 to 40 times less than the stiffness of the graft, increasing the stiffness of an ACL replacement would be best achieved by selecting fixation methods with higher stiffness and not by either shortening the graft or increasing the cross-sectional area of the graft.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Femoral Condyle Fracture during Anterior Cruciate Ligament Reconstruction

Dear Editor,We have greatly enjoyed reading the case report entitled “‘Femoral Condyle Fracture during Revision of Anterior Cruciate Ligament Reconstruction: Case Report and a Review of Literature in the issue of Arch Bone Jt Surg. 2015;3(2) with great interest. We would like to commend the authors for their detailed and valuable work. Although various case reports have described postoperative ...

متن کامل

Femoral Condyle Fracture during Revision of Anterior Cruciate Ligament Reconstruction: Case Report and a Review of Literature

 Background: A rare and devastating complication following anterior cruciate ligament (ACL) revision reconstruction is femoral fracture.    Case presentation: A 35-year old male soccer player with a history of ACL tear from the previous year ago, who underwent arthroscopic ACL reconstruction and functioned well until another similar injury caused ACL re-rupture. Revision of ACL reconstruction w...

متن کامل

Functional Outcome Following Arthroscopic ACL Reconstruction with Rigid Fix: A Retrospective Observational Study

  Background: No uniform consensus exists to decide type of fixation for arthroscopic anterior cruciate ligament reconstruction. Hypothsis: There is similar functional outcome after rigid fix compared to other methods of fixation which has been published. Study design: Retrospective observational study. Methods: A total of 50 patients underwent arthroscopic anterior cruciate ligament reconstruc...

متن کامل

High-stiffness distal fixation restores anterior laxity and stiffness as well as joint line fixation with an interference screw.

BACKGROUND Fixation of an anterior cruciate ligament graft at the joint line with an interference screw restores anterior laxity better than low-stiffness distal fixation with double staples and sutures tied to a post at implantation in porcine bone. HYPOTHESIS Fixation of an anterior cruciate ligament graft with a high-stiffness distal fixation device restores anterior laxity and knee stiffn...

متن کامل

Compaction of a bone dowel in the tibial tunnel improves the fixation stiffness of a soft tissue anterior cruciate ligament graft: an in vitro study in calf tibia.

BACKGROUND Despite increasing attention on fixation of a soft tissue anterior cruciate ligament graft in the tibia, there have been no studies on the use of a bone dowel as a joint line fixation device for promoting fixation properties, especially stiffness at the time of implantation. PURPOSE To determine whether compacting a bone dowel into the tibial tunnel improves fixation stiffness, yie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association

دوره 15 4  شماره 

صفحات  -

تاریخ انتشار 1999