Gap formation in transpatellar patellar tendon repair: pretensioning Krackow sutures versus standard repair in a cadaver model.
نویسندگان
چکیده
BACKGROUND Postfixation loosening within the Krackow stitch-tendon construct may be associated with gap formation in patellar tendon repair. HYPOTHESIS Pretensioning the Krackow stitch-tendon construct decreases postfixation gap formation in transpatellar patellar tendon repair. STUDY DESIGN Controlled laboratory study. METHODS Patellar tendon rupture was simulated in 8 pairs of cadaveric knees. Standard manual traction was used in all specimens to remove Krackow stitch slack. In the experimental group, specimens were pretensioned with a simulated active concentric quadriceps contraction with cycling of the knee 10 times from 90 degrees to 5 degrees of flexion. All specimens were then cycled at 0.25 Hz from 90 degrees to 5 degrees for 1000 cycles until failure, which was defined as 3 or 5 mm of gap formation. RESULTS A 3-mm gap occurred at 1 cycle (mean, 3.5 mm) and 35 cycles (4.0 mm) in the control and experimental groups, respectively. Gapping of 5 mm occurred at 35 (5.9 mm) and 100 cycles (5.0 mm) in the control and experimental specimens, respectively. Gap formation was smaller in the experimental group through 100 cycles (P < .05). CONCLUSION Gapping was lower with pretensioning in the early cycling stages. However, significant gapping occurred in both groups with repetitive concentric active loading ranging from 90 degrees to 5 degrees of flexion. CLINICAL RELEVANCE Tightening of the Krackow stitch as done in this study does not result in a clinically important decrease in gapping. This observation may be generalizable to other applications of the Krackow stitch.
منابع مشابه
Xenograft scaffold full-wrap reinforcement of Krackow achilles tendon repair.
Standard 4-strand repair of Achilles tendon tears is effective, but additional strength may be desirable in patients who are compromised or those with reruptures. Use of a xenograft scaffold has not been investigated biomechanically in Achilles tendon repair. This study compared stiffness, gap formation, and ultimate load to failure with Krackow repair vs Krackow repair augmented with xenograft...
متن کاملBiomechanical Evaluation of Patellar Tendon Repair Techniques: Comparison of Double Krackow Stitch with and without Cerclage Augmentation
The purpose of this study was to evaluate two different repair techniques for the primary repair of patellar tendon ruptures. Using a cadaveric model, we biomechanically compared a double Krackow stitch with, and without cerclage augmentation. The specimens were tested at loads comparable to those likely to be encountered during an early rehabilitation program (approximately 40 Newtons) and for...
متن کاملThe strength of surgical repairs of the rotator cuff. A biomechanical study on cadavers.
Using 26 cadaver shoulders, we produced a standard defect in the supraspinatus tendon and performed one of three types of repair. Their strength was found by testing in tension the force required to produce a gap of 3 mm, then 6 mm, and finally total disruption of the repair. The use of a polyethylene patch to spread the forces over the lateral bone surface and of extra sutures to grasp the ten...
متن کاملRepair of patellar tendon rupture with suture anchors.
Repair of a ruptured patellar tendon is usually performed with the use of sutures that are passed through intraosseous tunnels within the patella. However, a number of caveats pertain to this method. The Beath pin may penetrate the articular surface or may unduly injure the quadriceps through multiple passes. The already injured patellar tendon may be overly shortened after debridement and inse...
متن کاملA reliable and reproducible method for establishing accurate patella drill holes for quadriceps tendon repair
BACKGROUND Various techniques for quadriceps tendon repair have been described with biomechanical studies suggesting greater failure threshold with longitudinally placed drill holes. 1 The current gold standard for repair uses 3–4 sutures 2 passed through parallel longitudinal transpatel-lar bone tunnels. We describe a simple and reproducible technique Figure 1 Acufex ® Director™ Drill Guide po...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The American journal of sports medicine
دوره 38 1 شماره
صفحات -
تاریخ انتشار 2010