Scan-Rescan Reproducibility of Carotid Geometric Parameters using Bright Blood MRI at 3.0T
نویسندگان
چکیده
Y. Xue, D. S. Hippe, H. R. Underhill, M. S. Ferguson, N. Balu, R. Li, H. Chen, L. Dong, F. Li, G. Canton, and C. Yuan Vascular Imaging Laboratory, Radiology, University of Washington, Seattle, WA, United States, Center for Bio-Medical Imaging Research, Tsinghua University, Beijing, China, People's Republic of, Department of Radiology, Beijing Anzhen Hospital, Beijing, China, People's Republic of, Department of Radiology, Peking University First
منابع مشابه
Reproducibility of Dynamic Contrast-Enhanced MRI in Renal Cell Carcinoma
The objective of this study was to investigate the intra- and interobserver as well as scan-rescan reproducibility of quantitative parameters of renal cell carcinomas (RCCs) with dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). A total of 21 patients with clear cell RCCs (17 men, 4 woman; age 37-69 years, mean age 54.6 years, mean size, 5.0 ± 2.2 cm) were prospectively recruited ...
متن کاملIncreasing the Spatial Resolution of 3T Carotid MRI Has No Beneficial Effect for Plaque Component Measurement Reproducibility
PURPOSE Different in-plane resolutions have been used for carotid 3T MRI. We compared the reproducibility, as well as the within- and between reader variability of high and routinely used spatial resolution in scans of patients with atherosclerotic carotid artery disease. Since no consensus exists about the optimal segmentation method, we analysed all imaging data using two different segmentati...
متن کاملFabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System
Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...
متن کاملIVIM parameters have good scan-rescan reproducibility when evidential motion contaminated and poorly fitted image data are removed
Background: Intravoxel Incoherent Motion (IVIM) diffusion MRI is a promising technique for liver pathology evaluation, but this technique’s scan-rescan reproducibility has been reported to be unsatisfactory. Objective: To understand whether IVIM MRI parameters for liver parenchyma can be good after removal of motion contaminated and/or poorly fitted image data. Materials and Methods: Eighteen h...
متن کاملFabrication of New 3D Phantom for the measurement of Geometric Distortion in Magnetic Resonance Imaging System
Introduction: Geometric distortion, an important parameter in neurology and oncology. The current study aimed to design and construct a new three-dimensional (3D) phantom using a 3D printer in order to measure geometric distortion and its 3D reproducibility. Material and Methods: In this study, a new phantom ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2010