We retrospectively reviewed the records of 1150 computer-assisted total knee replacements and analysed the clinical and radiological outcomes of 45 knees that had arthritis with a pre-operative recurvatum deformity. The mean pre-operative hyperextension deformity of 11° (6° to 15°), as measured by navigation at the start of the operation, improved to a mean flexion deformity of 3.1° (0° to 7°) post-operatively. A total of 41 knees (91%) were managed using inserts ≤ 12.5 mm thick, and none had mediolateral laxity > 2 mm from a mechanical axis of 0° at the end of the surgery. At a mean follow-up of 26.4 months (13 to 48) there was significant improvement in the mean Knee Society, Oxford knee and Western Ontario and McMaster Universities Osteoarthritis Index scores compared with the pre-operative values. The mean knee flexion improved from 105° (80° to 125°) pre-operatively to 131° (120° to 145°), and none of the limbs had recurrent recurvatum. These early results show that total knee replacement using computer navigation and an algorithmic approach for arthritic knees with a recurvatum deformity can give excellent radiological and functional outcomes without recurrent deformity.
منابع مشابه
Total knee replacement with intra-articular resection of bone after malunion of a femoral fracture: can sagittal angulation be corrected?
Intra-articular resection of bone with soft-tissue balancing and total knee replacement (TKR) has been described for the treatment of patients with severe osteoarthritis of the knee associated with an ipsilateral malunited femoral fracture. However, the extent to which deformity in the sagittal plane can be corrected has not been addressed. We treated 12 patients with severe arthritis of the kn...
متن کاملGenu Recurvatum versus Fixed Flexion after Total Knee Arthroplasty
BACKGROUND To date, there is no study comparing outcomes between post-total knee replacement genu recurvatum and fixed flexion. This study aims to provide data that will help in deciding which side to err on when neutral extension is not achieved. METHODS A prospective cohort study of primary total knee arthroplasties was performed, which compared the 6-month and 2-year clinical outcomes betw...
متن کاملGenu recurvatum as a complication after total knee arthroplasty.
A 73-year-old female patient underwent total knee arthroplasty for arthrosis. After surgery, recurvatum instability over 55 degrees occurred. Two years later, primary endoprosthesis was removed and a revision endoprosthesis implanted. However, complete deformity occurred again. Two years later, the thickest revision polyethylene tibial implant was implanted on the same endoprosthesis. In spite ...
متن کاملNavigated shorter incision or smaller implant in knee arthritis?
Minimally invasive approaches for unicompartmental knee arthroplasty are well-accepted for treating knee arthritis because of the smaller implant size, shorter operative time, and tissue-sparing nature of the procedure. With the introduction of computer alignment systems, a well-aligned and balanced total knee arthroplasty (TKA) can be achieved even with smaller surgical exposures. We hypothesi...
متن کاملLATE GENU-RECURVATUM AFTER TOTAL KNEE REPLACEMENT: TWO CASES REPORT AND REVIEW OF LITERATURES
This was Presented in 5th International Congress of Iranian Iranian Society of Knee Surgery, Arthroscopy, and Sports Traumatology (ISKAST), 14-17 Feb 2018- Kish, Iran
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 94 5 شماره
صفحات -
تاریخ انتشار 2012