Imaging of protein crystals with two-photon microscopy.

نویسندگان

  • Pius Padayatti
  • Grazyna Palczewska
  • Wenyu Sun
  • Krzysztof Palczewski
  • David Salom
چکیده

Second-order nonlinear optical imaging of chiral crystals (SONICC), which portrays second-harmonic generation (SHG) by noncentrosymmetric crystals, is emerging as a powerful imaging technique for protein crystals in media opaque to visible light because of its high signal-to-noise ratio. Here we report the incorporation of both SONICC and two-photon excited fluorescence (TPEF) into one imaging system that allows visualization of crystals as small as ~10 μm in their longest dimension. Using this system, we then documented an inverse correlation between the level of symmetry in examined crystals and the intensity of their SHG. Moreover, because of blue-green TPEF exhibited by most tested protein crystals, we also could identify and image SHG-silent protein crystals. Our experimental data suggest that the TPEF in protein crystals is mainly caused by the oxidation of tryptophan residues. Additionally, we found that unspecific fluorescent dyes are able to bind to lysozyme crystals and enhance their detection by TPEF. We finally confirmed that the observed fluorescence was generated by a two-photon rather than a three-photon process. The capability for imaging small protein crystals in turbid or opaque media with nondamaging infrared light in a single system makes the combination of SHG and intrinsic visible TPEF a powerful tool for nondestructive protein crystal identification and characterization during crystallization trials.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

RESEARCH ARTICLES Macromolecular Impurities and Disorder in Protein Crystals

The mechanisms by which macromolecular impurities degrade the diffraction properties of protein crystals have been investigated using X-ray topography, high-resolution diffraction line shape measurements, crystallographic data collection, chemical analysis, and two-photon excitation fluorescence microscopy. Hen egg-white lysozyme crystals grown from solutions containing a structurally unrelated...

متن کامل

Comparison of ScintSim1 and Geant4 Monte Carlo simulation codes for optical photon transport in thick segmented scintillator arrays

  Introduction: Arrays of segmented scintillation crystals are useful in megavoltage x-ray imaging detectors for image-guided radiotherapy. Most previous theoretical studies on these detectors have modelled only ionizing-radiation transport. Scintillation light also affects detector performance. ScintSim1, our previously reported optical Monte Carlo code for such detector...

متن کامل

Liquid crystal director dynamics imaged using two-photon fluorescence microscopy with remote focusing.

We introduce a novel imaging technique adopting remote focusing for resolving the axial dynamics in the director field for liquid crystals. The high axial time resolution of our approach is demonstrated by imaging directly the evolution of the director field for an initially splayed nematic layer subject to a sudden voltage pulse. Images of the switching dynamics are presented, revealing transi...

متن کامل

Coherent anti-Stokes Raman scattering polarized microscopy of three-dimensional director structures in liquid crystals

We demonstrate three-dimensional vibrational imaging of director structures in liquid crystals using coherent anti-Stokes Raman scattering sCARSd polarized microscopy. Spatial mapping of the structures is based on sensitivity of a polarized CARS signal to the orientation of anisotropic molecules in liquid crystals. As an example, we study structures in a smectic material and demonstrate that si...

متن کامل

Fast two-dimensional grid and transmission X-ray microscopy scanning methods for visualizing and characterizing protein crystals

A fast continuous grid scan protocol has been incorporated into the Swiss Light Source (SLS) data acquisition and analysis software suite on the macromolecular crystallography (MX) beamlines. Its combination with fast readout single-photon counting hybrid pixel array detectors (PILATUS and EIGER) allows for diffraction-based identification of crystal diffraction hotspots and the location and ce...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Biochemistry

دوره 51 8  شماره 

صفحات  -

تاریخ انتشار 2012