The effects of static charge in spacer devices on glucocorticosteroid aerosol deposition in asthmatic patients.

نویسندگان

  • C J Kenyon
  • L Thorsson
  • L Borgström
  • S P Newman
چکیده

Electrostatic charge in plastic spacer devices has been shown in vitro to reduce delivery of asthma medications intended for inhalation, but the effect of static charge on in vivo drug deposition is unknown. A six-way randomized crossover study was conducted in 10 mild asthmatic patients. Two plastic spacers (Nebuhaler and Volumatic) and one metal spacer (Nebuchamber) were tested. The spacers were used either "primed" or "unprimed". Priming was performed by firing 20 doses of placebo aerosol into a new spacer, hence coating the inner surface with surfactant and minimizing static charge. Unprimed spacers were new and were not treated. Pressurized aerosol canisters delivering budesonide (200 microg Pulmicort) were radiolabelled with the radionuclide 99mTc and lung deposition was measured by gamma scintigraphy. The radiolabel was shown to be a valid marker for the drug substance prior to the clinical phase of the study. Priming significantly increased mean whole lung deposition following inhalation from plastic spacers (Nebuhaler primed 37.7% and unprimed 26.7%, p=0.01; Volumatic primed 32.0% and unprimed 22.1%, p=0.02). Priming had no effect on the mean whole lung deposition following inhalation from the Nebuchamber (primed 33.5% and unprimed 32.9%). Lung deposition in vivo from plastic spacer devices will vary according to the electrostatic charge on the spacer walls. Priming reduces retention of drug on plastic spacer devices and increases lung deposition. Metal spacers are not susceptible to static charge, which should result in more predictable lung deposition.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Variability of aerosol delivery via spacer devices in young asthmatic children in daily life.

Pressurized metered dose inhalers (pMDI) are widely used together with spacers for the treatment of asthma in children. However, the variability of daily medication dose for pMDI/spacer combinations is not known. Electrostatic charge is a potential source of dose variability. Metal spacers have no static charge. This study assessed and compared within-subject variability of aerosol delivery of ...

متن کامل

Evaluation of Proper Usage of Glucocorticosteroid Inhalers and Their Adverse Effects in Asthmatic Patients

BACKGROUND The frequent use of corticosteroid inhalers (CSIs), especially at higher doses, has been accompanied by concern about both systemic and local adverse reactions. The local adverse reactions of inhaled corticosteroids (ICSs) are considered to constitute infrequent and minor problems. However, while not usually serious, these local adverse reactions are of clinical importance. This stud...

متن کامل

[Evaluation of the influence of patient age and spacer device volume on aerosol lung deposition].

OBJECTIVE To evaluate the efficacy of three frequently used spacer devices to deliver aerosol to the lung, and to compare radioaerosol deposition with each device in different age groups. METHODS Nine healthy, non-smoking volunteers were recruited: three adults and six children, including three toddlers and three school age children. Qualitative and semi-quantitative analysis of radioaerosol ...

متن کامل

تأثیر استفاده از اسپری‌های استنشاقی با و بدون استفاده از آسم یار بر میزان اشباع اکسیژن خون در بیماران مبتلا به آسم

Abstract Background & Aim: Asthma is the most common respiratory tract disease. One of the drugs prescribing in the patients with asthma is inhalation spray or inhaler that is used with or without spacer. The effect of spacer on improving patients with asthma has always been under discussion. Hence, the aim of the current study was to determine the effectiveness of using inhaler on arterial O2...

متن کامل

Factors affecting the efficiency of aerosol therapy with pressurised metered-dose inhalers through plastic spacers.

AIM The main objective of this study was to compare the in vitro delivery of salbutamol from a chlorofluorocarbon(CFC)-propelled pressurised metered-dose inhaler (pMDI) versus a newly developed hydrofluoroalkane(HFA)-propelled pMDI through various spacers. In addition, we aimed to study the effect on bronchodilator response when using an optimal pMDI/spacer combination for aerosol delivery comp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The European respiratory journal

دوره 11 3  شماره 

صفحات  -

تاریخ انتشار 1998