Comparison of the international normalized ratio levels obtained by portable coagulometer and laboratory in a clinic specializing in oral anticoagulation.
نویسندگان
چکیده
INTRODUCTION Therapy with Vitamin K antagonists (VKA) is effective in reducing thromboembolic events in various diseases. There are limitations however, which limit clinical handling and maintaining INR within therapeutic range. Studies have shown that portable coagulometers, when compared to laboratory tests, are more practical and provide better patient adherence and involvement toward treatment which results in better INR control. This study aimed to evaluate laboratory obtained INR results compared to two different portable coagulometers. METHODS A prospective study which monitored 1009 patients using VKA in the Anticoagulation Clinic at the Institute Dante Pazzanese of Cardiology in São Paulo between July and September 2012. Patient INR values were obtained by the laboratory through venipuncture and then compared to INR values obtained by capillary puncture from two different portable coagulometers. RESULTS Overall, 1009 patients were included in the study; among these, 520 (51.5%) are male with average age of 59.6 years (13-91). The more common indications were atrial fibrillation (49.9%) and mechanical prosthesis (33.7%). The correlation coefficient was of 0.95 with and 0.88 with INRatio PT Monitor(®) compared to laboratory. In patients with INR < 2 (lower than therapeutic range), the coefficient was 0.92 and 0.81 for CoaguChek XS plus(®) and INRatio PT Monitor(®) respectively. In patients within therapeutic range (INR 2-3), the coefficient was 0.86 with CoaguChek XS Plus(®) and 0.76 with INRatio PT Monitor(®) . For INR above therapeutic range (INR > 3.0) the correlation was 0.80 with CoaguChek XS Plus(®) and 0.54 with INRatio PT Monitor(®) . As for concordance between methods, the intraclass correlation coefficients (ICC) were slightly smaller than those previously stated (ICC = 0.899 with CoaguChek XS Plus(®) and ICC = 0.716 with INRatio PT Monitor(®) ). CONCLUSION The use of portable coagulometers was comparable to laboratory tests and better correlation coefficients were observed with CoaguChek XS Plus(®) and in patients with INR lower or within therapeutic range. Portable coagulometers proved to be a useful and reliable tool for INR control in patients using VKA.
منابع مشابه
Security and cost comparison of INR self-testing and conventional hospital INR testing in patients with mechanical heart valve replacement
BACKGROUND International normalized ratio (INR) self-testing can improve the management of anticoagulation therapy with warfarin for the patients following mechanical heart valve replacement. Several reviews and studies have demonstrated self-management as an option to improve patient's outcome considerably after mechanical heart valve replacement. We sought to analyze the security, economy and...
متن کاملClinical Utility and Accuracy of Coaguchek XS, a Reliable Alternative to Laboratory International Normalized Ratio Monitoring in Korean Patients With Atrial Fibrillation
Background and Objectives: To evaluate the accuracy and the clinical utility of the Coaguchek XS, a portable point-of-care coagulometer, compared to standard laboratory methods in Korean patients. Subjects and Methods: We included 107 patients with atrial fibrillation on long-term oral warfarin therapy. The prothrombin time as expressed by the international normalized ratio (INR) was measured b...
متن کاملFactors determining patients’ intentions to use point-of-care testing medical devices for self-monitoring: the case of international normalized ratio self-testing
PURPOSE To identify factors that determine patients' intentions to use point-of-care medical devices, ie, portable coagulometer devices for self-testing of the international normalized ratio (INR) required for ongoing monitoring of blood-coagulation intensity among patients on long-term oral anticoagulation therapy with vitamin K antagonists, eg, warfarin. METHODS A cross-sectional study that...
متن کاملComparative study of a portable prothrombin time monitor employing three different systems in oral anticoagulant units.
The aim of this study was to evaluate the accuracy of the portable coagulometer CoaguChek (Roche Diagnostics) as a prothrombin time (PT) monitor, and to correlate capillary blood results with those of three different routine methods used for monitoring oral anticoagulant therapy (OAT): capillary, plasma and whole blood samples. Three hospitals participated in the study with a total of 235 patie...
متن کاملComparison of the quality of oral anticoagulant therapy through patient self-management and management by specialized anticoagulation clinics in the Netherlands: a randomized clinical trial.
BACKGROUND Several studies have demonstrated that patient self-management of oral anticoagulant therapy (OAT) can improve treatment quality. However, most of these studies were not conducted within a specialized anticoagulation care system. The objective of the present study was to determine whether patient self-management of OAT improves the quality of care delivered by anticoagulation clinics...