Accuracy of the unipolar electrogram for identification of the site of origin of ventricular activation.

نویسندگان

  • K C Man
  • E G Daoud
  • B P Knight
  • M Bahu
  • R Weiss
  • A Zivin
  • S J Souza
  • R Goyal
  • S A Strickberger
  • F Morady
چکیده

INTRODUCTION The purpose of this study was to determine the accuracy of the unipolar electrogram for identifying the earliest site of ventricular activation. The earliest site of ventricular activation may be identified with the unipolar electrogram by the absence of an R wave. However, the accuracy of this technique is unknown. METHODS AND RESULTS A single ventricular premature complex was induced mechanically at the tip of an electrode catheter to simulate a ventricular premature depolarization site of origin. Unipolar electrograms were recorded from the right ventricular septum at the tip electrode and at 2, 5, 8, and 11 mm from the electrode tip in 20 patients. No R waves were detected at the ventricular premature depolarization site of origin. R waves were detected in 4 of 20 patients (20%) at 2 mm from the tip electrode and 7 of 20 patients (35%) at 5, 8, and 11 mm from the tip electrode. An R wave was not observed at distances < or = 11 mm from the site of tachycardia origin in 13 of 20 patients (65%). CONCLUSIONS While an R wave in the unipolar electrogram can be seen as close as 2 mm from the site of impulse origin, the absence of an R wave as an indicator of the site of impulse origin in the right ventricle is highly inaccurate. Therefore, the absence of an R wave in the unipolar electrogram is unlikely to be an adequate guide for identification of an effective target site for ablation of right ventricular tachycardia.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Identification of ventricular tachycardia using intracardiac electrograms: a comparison of unipolar versus bipolar waveform analysis.

Implantable antitachycardia devices suffer a high false-positive rate of delivery of therapy because current detection schemes based upon ventricular rate and rate variations are excessively sensitive at the cost of specificity. Several methods have been proposed for providing complementary information derived from morphologic analysis of intraventricular electrograms in order to increase speci...

متن کامل

Novel algorithmic methods in mapping of atrial and ventricular tachycardia.

BACKGROUND Conventional methods to assess local activation time (LAT) detect the peak of the bipolar electrogram (B-LATPeak) or the maximal negative slope of the unipolar electrogram (U-LATSlope). We evaluated 3 novel methods to assess LAT: onset (B-LATOnset) and center of mass (B-LATCoM) of bipolar electrogram, and maximal negative slope of unipolar electrogram within a predefined bipolar wind...

متن کامل

Radiofrequency Catheter Ablation with the Use of a Noncontact Mapping System for Ventricular Tachycardia Originating from the Aortic Sinus Cusp —A Case Report—

Here we present a 15-year old female in whom an idiopathic ventricular tachycardia (VT) originating from the left aortic sinus cusp was eliminated by radiofrequency catheter ablation (RFCA) under navigation using a noncontact mapping system (NCM). The dynamic activation map constructed with the NCM clearly identified a VT focus in the left aortic sinus cusp, from which the activation spread out...

متن کامل

Determination of Transmural Location of Onset of Activation From Cardiac Surface Electrograms

Methods of estimating depth of origin of ventricular activation from cardiac surface electrograms were evaluated in experiments on eight dogs. The ventricles were paced via multielectrode needle arrays placed transmurally in from four to six locations in the wall of the left ventricle. A multiplexed data-recording system was used to simultaneously record from 64 unipolar cardiac surface electro...

متن کامل

Determination of transmural location of onset of activation from cardiac surface electrograms.

Methods of estimating depth of origin of ventricular activation from cardiac surface electrograms were evaluated in experiments on eight dogs. The ventricles were paced via multielectrode needle arrays placed transmurally in from four to six locations in the wall of the left ventricle. A multiplexed data-recording system was used to simultaneously record from 64 unipolar cardiac surface electro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of cardiovascular electrophysiology

دوره 8 9  شماره 

صفحات  -

تاریخ انتشار 1997