Tc-99m-ECD SPECT as the measure for therapeutic response in patients with cobalamin deficiency

نویسندگان

  • Min-Chien Tu
  • Chung-Ping Lo
  • Ching-Yuan Chen
چکیده

BACKGROUND Cobalamin (Cbl) is an essential vitamin for human health. While an increasing body of evidence supports the negative impact of Cbl deficiency on cognition, the causality has yet to be determined, and the reported therapeutic responses after Cbl supplement therapy have been inconsistent. Besides, few reports have described neuroimaging characteristics associated with the therapeutic response. METHODS To describe and compare technetium-99m ethyl cysteinate dimer single-photon emission computed tomography (Tc-99m-ECD SPECT) findings in 2 patients with Cbl deficiency with distinct therapeutic responses. RESULTS Case 1 scored 12/30 in the mini-mental state examination (MMSE) and 34/100 in the cognitive abilities screening instrument (CASI). Profound deficits in mental manipulation, drawing, short-term/long-term memory, and verbal fluency were noted. Case 2 scored 24/30 in the MMSE and 78/100 in the CASI, mainly due to impaired mental manipulation, abstract thinking, and borderline performance in short-term memory and verbal fluency. While both cases showed widespread hypoperfusion within bilateral frontotemporal regions and thalamus on Tc-99m-ECD SPECT, Case 2 demonstrated relatively preserved radio-uptake in the frontal regions, especially the anterior cingulate cortex (ACC) and prefrontal cortex (PFC), consistent with the better therapeutic response (Case 1: 12/30 to 11/30 in the MMSE; Case 2: 24/30 to 28/30 in the MMSE). CONCLUSION Given that the ACC integrates the limbic system and frontosubcortical circuits and the PFC governs executive function, the extent and severity of hypofrontality may be responsible for the worse prognosis. Our Tc-99m-ECD SPECT observations revealed that the negative impact on cerebral metabolic tone is relevant to the severity of Cbl deficiency, and the functional integrity of the ACC and PFC is highly associated with the preservation of global cognitive function in our cases with Cbl deficiency.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation of Tc-99 m ethyl cysteinate dimer single-photon emission computed tomography and clinical presentations in patients with low cobalamin status.

BACKGROUND Cobalamin (Cbl) deficiency has been associated with various neuropsychiatric symptoms of different severities. While some studies dedicated in structural neuroimaging credibly address negative impact of low Cbl status, functional imaging reports are limited. We herein retrospectively review the correlation of Tc-99 m ethyl cysteinate dimer single-photon emission computed tomography (...

متن کامل

Atypical finding of brain Tc-99m-ECD SPECT imaging in herpes simplex encephalitis.

Lesions in acute herpes simplex encephalitis (HSE) have been reported to show decreased uptake of Tc-99m ethyl cysteinate dimer (ECD). A patient with acute HSE displaying a lesion in the left temporal lobe was evaluated by means of Tc-99m ECD single-photon emission computed tomography (SPECT). Dynamic SPECT images indicated regionally increased uptake of tracer in the ipsilateral temporal lobe ...

متن کامل

Decreased perfusion of the bilateral thalami in patients with chronic pain detected by Tc-99m-ECD SPECT with statistical parametric mapping.

The purpose of this study was to examine whether the Tc-99m-ECD SPECT can detect any difference between the brain perfusion in patients with chronic pain and normal controls by means of the Statistical Parametric Mapping (SPM96). The subjects were twelve patients with chronic pain (CP group) and twelve normal controls (NC group). After informed consent was obtained, 720 MBq of Tc-99m-ECD was in...

متن کامل

Role of 99mTc-ECD SPECT in the Management of Children with Craniosynostosis

PURPOSE OF THE REPORT There is a paucity of data on correlation of various imaging modalities with clinical findings in craniosynostosis. Moreover, no study has specifically reported the role of (99m)Tc-ECD SPECT in a large number of subjects with craniosynostosis. MATERIALS AND METHODS We prospectively analyzed a cohort of 85 patients with craniosynostosis from year 2007 to 2012. All patient...

متن کامل

Direct comparison of 99mTc-PSMA SPECT/CT and 68Ga-PSMA PET/CT in patients with prostate cancer

Objective(s): 99mTc-PSMA SPECT/CT is a cost effective alternative for 68Ga-PSMA PET/CT. The aim of this study was to directly compare these two techniques in patients with prostate cancer. Methods: 28 man with prostate cancer were studied using 99mTc-PSMA SPECT/CT and 68Ga-PSMA PET/CT in a shor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 95  شماره 

صفحات  -

تاریخ انتشار 2016