Clinical Applications of Esophageal Multichannel Intraluminal Impedance Testing.

نویسندگان

  • Radu Tutuian
  • Donald O Castell
چکیده

Multichannel intraluminal impedance is a relatively new technology that allows detection of bolus movement in the gastrointestinal tract without the use of radiation. In clinical applications it is combined with manometry, allowing a better evaluation of the functional characteristics (ie, bolus transit) of esophageal motility abnormalities. When combined with pH monitoring, it provides more comprehensive data on both acid and nonacid gastroesophageal reflux.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Esophageal Multichannel Intraluminal Impedance and pH Monitoring in the Evaluation of Achalasia and Gastroesophageal Reflux Disease in a Child with Down Syndrome: a Case Report.

We report the case of a rare association between achalasia and Down syndrome in a child presenting with symptoms that suggest a gastroesophageal reflux. Evaluation of the patient with 24-hour multichannel intraluminal impedance and pH recording and upper endoscopy lead to the diagnosis of achalasia. However, the persistence of the symptoms after the concurrent surgical myomectomy and fundoplica...

متن کامل

Critical Analysis of Esophageal Multichannel Intraluminal Impedance Monitoring 20 Years Later

Multichannel intraluminal impedance (MII) for the evaluation of esophageal diseases was created in 1991 trying to solve previous limitations of esophageal function test. MII-pH is able to determine the physical characteristics of the refluxate (liquid, gas, or mixed) and nonacidic GER. MII-manometry can determine the presence of bolus and its relation with peristalsis. This paper makes a critic...

متن کامل

Correlation of Gastroesophageal reflux disease Assessment Symptom Questionnaire to impedance-pH measurements in children

Background Esophageal multichannel intraluminal impedance-pH monitoring has become one of the preferred tests to correlate observed reflux-like behaviors with esophageal reflux events. The Gastroesophageal reflux disease Assessment Symptom Questionnaire is a validated tool used to distinguish infants with gastroesophageal reflux disease from healthy children. The aim of this study was to determ...

متن کامل

Principles of Combined Esophageal Impedance-ph Monitoring in Children: Indications, Benefits and Limitations

The standard test for suspected gastroesophageal refl ux is pH monitoring. However, the majority of gastroesophageal refl ux episodes in infants and children are nonacidic (pH > 4) and extraesophageal symptoms apparently can be caused by both acidic (pH < 4) and nonacidic refl ux. In order to overcome these aspects, a new technique has been developed and placed under scrutiny in the past twenty...

متن کامل

Diagnostic difficulties during combined multichannel intraluminal impedance and pH monitoring in patients with esophagitis or Barrett's esophagus.

Gastroesophageal reflux disease (GERD) is one of the most common esophageal diseases in developed countries. It is widely believed that GERD symptoms are caused by acid refluxate within the esophagus, so ambulatory 24 hour pH-monitoring became the gold standard in detecting gastroesophageal reflux. Traditional ambulatory pH monitoring is unable to detect a gastroesophageal reflux with pH >4. Th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Gastroenterology & hepatology

دوره 2 4  شماره 

صفحات  -

تاریخ انتشار 2006