WE-C-217BCD-02: Design of an MR Compatible Rotating Anode X-Ray Tube.

نویسندگان

  • P Lillaney
  • M Shin
  • W Hinshaw
  • R Fahrig
چکیده

PURPOSE To design a rotating anode X-ray tube capable of operating in strong magnetic field environments. This tube design can be used in 'close proximity" hybrid X-ray/MR system geometries where the imaging fields of view are separated by only ∼1.2 meters. METHODS Existing rotating anode X-ray tube designs fail in strong magnetic field environments because the fields alter the electron trajectories in the tube and act as a brake on the induction motor, reducing the rotation speed of the anode. We propose an X- ray tube design that utilizes optimized resistive coils to shield a fraction of the MR fringe field. The remainder of the correction is performed using bias voltages on electrodes adjacent to the x-ray tube filament. Furthermore, we replace the induction motor with a novel motor design that is analogous to a three-phase brushed DC motor with the MR fringe field serving as the stator field. RESULTS Space charge simulations of the electron optics show that the combined magnetostatic/electrostatic method can correct for a magnetic field strength of 152 mT with approximately 590 A/cm2 applied to the shielding coils and a 35 kV potential difference applied to the bias electrodes. A prototype of the motor design was machined and assembled. The performance of this prototype motor was evaluated at various magnetic field strengths, and was found to accelerate to the minimum operating speed of 3000 rpm in 10 seconds for an external field of 60 mT. CONCLUSIONS The space charge simulations validate that the electron trajectories can be controlled using our combined approach. Testing of the motor prototype demonstrates that our design outperforms existing induction motors in strong magnetic field environments. Integrating this design with our modified flat panel detector will allow, for the first time, a "close proximity" hybrid system in which imaging performance is not compromised. NIH R01 EB007626 Richard M. Lucas Foundation Stanford Bio-X Fellowship.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New x-ray tube performance in computed tomography by introducing the rotating envelope tube technology.

The future demands of computed tomography imaging regarding the x-ray source can be summarized with higher scan power, shorter rotation times, shorter cool down times and smaller focal spots. We report on a new tube technology satisfying all these demands by making use of a novel cooling principle on one hand and of a novel beam control system on the other hand. Nowadays tubes use a rotating an...

متن کامل

A practical method to determine the healing and cooling curves of x-ray tube assemblies.

A practical method to determine the heating and cooling curves of x-ray tube assemblies with rotating anode x-ray tube is proposed. Available procedures to obtain these curves as described in the literature are performed during operation of the equipment, and the precision of the method depends on the knowledge of the total energy applied in the system. In the present work we describe procedure...

متن کامل

A truly hybrid interventional MR/X-ray system: feasibility demonstration.

A system enabling both x-ray fluoroscopy and MRI in a single exam, without requiring patient repositioning, would be a powerful tool for image-guided interventions. We studied the technical issues related to acquisition of x-ray images inside an open MRI system (GE Signa SP). The system includes a flat-panel x-ray detector (GE Medical Systems) placed under the patient bed, a fixed-anode x-ray t...

متن کامل

بررسی اثر پاشنه آند بر دوز دریافتی بیضه‌ها در رادیوگرافی لگن

Background: Anode heel effect refers to reduction of radiation intensity in the anode side of X-ray tube. This variation in radiation intensity across the anode-cathode of X-ray tube can be benefited for decrease radiation exposure in some radiological examinations. The aim of this study was to evaluate the effect of anode heel orientation on the radiation dose received by the testes in male pa...

متن کامل

Calculation of the X-Ray Spectrum of a Mammography System with Various Voltages and Different Anode-Filter Combinations Using MCNP Code

Introduction One of the best methods in the diagnosis and control of breast cancer is mammography. The importance of mammography is directly related to its value in the detection of breast cancer in the early stages, which leads to a more effective treatment. The purpose of this article was to calculate the X-ray spectrum in a mammography system with Monte Carlo codes, including MCNPX and MCNP5...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part27  شماره 

صفحات  -

تاریخ انتشار 2012