Intraarterial contrast-enhanced MR aortography with and without parallel acquisition technique in patients with peripheral arterial occlusive disease.

نویسندگان

  • Silke Potthast
  • Georg M Bongartz
  • Rolf Huegli
  • Anja-Carina Schulte
  • Jochen G Schwarz
  • Markus Aschwanden
  • Deniz Bilecen
چکیده

OBJECTIVE Repeated intraarterial gadolinium injections are necessary in endovascular MRI-guided interventions; therefore a low-dose protocol with a short acquisition time is preferable. The purpose of this study was to conduct a quantitative comparison of intraarterial MR aortograms obtained with and without high-speed parallel acquisition technique. SUBJECTS AND METHODS Intraarterial MR aortography was performed at 1.5 T on nine patients with peripheral arterial occlusive disease and in an aortic phantom with pulsatile flow. A 3D fast low-angle shot MRI sequence was used for standard technique (acquisition time, 20 seconds) and for parallel acquisition technique (acquisition time, 14 seconds). In all patients, a pigtail catheter was left in the suprarenal position after digital subtraction angiography. Contrast-enhanced intraarterial MR aortography was performed after automated injection of 50 mmol/L gadoterate dimeglumine at an injection rate of 4 mL/s. Contrast-to-noise ratio (CNR) and image quality were evaluated in both imaging series at different locations. In an aortic phantom with pulsatile flow, CNR was determined 1, 30, and 60 cm distal to the catheter tip with standard and parallel acquisition techniques. RESULTS In all patients, intraarterial MR aortography was feasible with both acquisition techniques. No significant difference in CNR or image quality was observed in the patient study. Similar results were calculated for the pulsatile aortic flow phantom at all locations. CONCLUSION Intraarterial MR aortography is feasible with parallel acquisition technique without a significant loss of CNR. This technique reduces contrast agent consumption approximately 30% owing to an approximately 30% reduction in acquisition time.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SNR Optimized Contrast-Enhanced MRA of the Peripheral Vasculature using Patient Specific Timing Parameters: Comparison between High and Conventional Relaxivity Contrast Agents in Patient Suspected of Arterial Occlusive Disease

Introduction Single injection moving table peripheral contrast enhanced MR angiography is increasingly utilized for the evaluation of peripheral atherosclerotic occlusive disease (PAOD). Peripheral MRA (pMRA) is typically performed using a moving table technique during first passage of double to triple dose (0.2-0.3 mmol/kg) extracellular gadolinium chelate. The objective of this study was to c...

متن کامل

Contrast Enhanced Echocardiography for Detection of Intrapulmonary Shunts in Liver Transplant Candidates

Background: Intrapulmonary vascular abnormalities associated with liver cirrhosis may result in intrapulmonary right-to-left shunt and hypoxemia. The aim of this study was to use contrast enhanced echocardiography to detect intrapulmonary vascular abnormalities in patients with liver cirrhosis candidates for liver transplantation. Methods: One hundred and two adult patients underwent contrast e...

متن کامل

Use of Parallel Imaging in Peripheral Contrast-enhanced Magnetic Resonance Angiography: Retrospective Study

Objective: To evaluate the application of a parallel imaging technique — generalised autocalibrating partially parallel acquisition — in peripheral contrast-enhanced magnetic resonance angiography. Patients and Methods: This was a retrospective review of 17 consecutive patients with peripheral vascular disease who underwent lower-extremity 3-dimensional contrast-enhanced magnetic resonance angi...

متن کامل

Assessment of directional Doppler ultrasound techniques in the diagnosis of carotid artery diseases.

Three diagnostic techniques based on the use of directional doppler ultrasound have been evaluated in comparison with direct percutaneous carotid angiography and arch aortography. The results indicate that the non-invasive techniques provide a safe, atraumatic method of assessing patients with symptoms of extracranial occlusive arterial disease.

متن کامل

Venous sinus occlusive disease: MR findings.

PURPOSE To study MR patterns of venous sinus occlusive disease and to relate them to the underlying pathophysiology by comparing the appearance and pathophysiologic features of venous sinus occlusive disease with those of arterial ischemic disease. METHODS The clinical data and MR examinations of 26 patients with venous sinus occlusive disease were retrospectively reviewed with special attent...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • AJR. American journal of roentgenology

دوره 188 3  شماره 

صفحات  -

تاریخ انتشار 2007