Dynamic analysis of above-knee amputee gait.

نویسندگان

  • Tae Soo Bae
  • Kuiwon Choi
  • Daehie Hong
  • Museong Mun
چکیده

BACKGROUND It is important to understand the characteristics of amputee gait to develop more functional prostheses. The aim of this study is to quantitatively evaluate amputee gait by dynamic analysis of the musculoskeletal system during level walking and stair climbing. METHODS Dynamic analysis using gait analysis, electromyography and musculoskeletal modeling for above-knee amputees (n=8) and healthy adults (n=10) was performed to evaluate the muscle balance, muscle force, and moment of each major muscle in each ambulatory task. Time-distance parameters and the kinematic parameter of gait analysis were calculated, and a root mean square electromyogram of major muscles and hamstring and tibialis anterior coactivity was measured using electromyography. Lastly, dynamic analyses of above-knee amputee gaits were performed using musculoskeletal models with scaled bones and redefined muscles for each subject. FINDINGS Most kinematic parameters showed statistically no difference among the tasks, excluding pelvic tilt, pelvic obliquity, and hip abduction. Major muscle activities and coactivities of the hamstring and tibialis anterior showed that the stair ascent task needed more muscle activity than the stair descent task and level walking. The muscle activity and coactivity of amputees were greater than those of healthy subjects, excluding the hamstring coactivity during stair ascent (P<0.05). Lastly, dynamic analysis showed that weakened abductor and excessive adductor and then inadequate torque during all tasks were quantitatively observed. INTERPRETATION Dynamic analysis of amputee gait enabled us to quantify the contribution of major muscles at the hip and knee joint mainly in daily ambulatory tasks of above-knee amputees and may be helpful in designing functional prostheses.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Asymmetric Knee Height on Gait Asymmetry for Unilateral Transfemoral Amputees

Transfemoral prostheses have traditionally sought to emulate symmetry in their designs. Using a symmetric prosthesis for a physically asymmetric unilateral transfemoral amputee typically causes asymmetric gait patterns. This research study investigates the effects of prostheses with lower knee heights than the intact knee and a pilot study of the combined effects of adding distal mass with lowe...

متن کامل

Repeatability of kinetic and kinematic measurements in gait studies of the lower limb amputee.

During the last few years considerable attention has been given to the use of gait analysis as a tool for clinical use. The instrumentation for measurement of the kinetics and kinematics of human locomotion was originally designed for research use. Extension of its use into the clinical field calls for simplified methodology and clearly defined protocols with precise identification of the relev...

متن کامل

Socket Flexion and Gait of an Above-knee, Bilateral Amputee.

1 Chief, Bioengineering Laboratory, Veterans Administration Prosthetics Center, 252 Seventh Ave., New York 1, N. Y. M ANY factors affect the gait of an aboveknee, bilateral amputee as he walks on his prostheses. Among the factors are his general health and strength, the length and condition of his stumps, the alignment of his prostheses, his comfort, and the type of knee units employed. While s...

متن کامل

Analysis of the swing phase dynamics and muscular effort of the above-knee amputee for varying prosthetic shank loads.

The purpose of this study was to determine the effect of varying prosthetic shank mass, while maintaining the mass centre location and moment of inertia, on the swing phase kinematics, kinetics and hip muscular effort of free speed above-knee (AK) amputee gait. Six AK amputees, wearing similar prosthetic designs, had three load conditions applied to their prosthetic shank: 1) Load 0-unloaded (X...

متن کامل

Differences in knee flexion between the Genium and C-Leg microprocessor knees while walking on level ground and ramps.

BACKGROUND Microprocessor knees have improved the gait and functional abilities of persons with transfemoral amputation. The Genium prosthetic knee offers an advanced sensor and control system designed to decrease impairment by: allowing greater stance phase flexion, easing transitions between gait phases, and compensating for changes in terrain. The aim of this study was to determine differenc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical biomechanics

دوره 22 5  شماره 

صفحات  -

تاریخ انتشار 2007