Four-dimensional (4D) image reconstruction strategies in dynamic PET: beyond conventional independent frame reconstruction.

نویسندگان

  • Arman Rahmim
  • Jing Tang
  • Habib Zaidi
چکیده

In this article, the authors review novel techniques in the emerging field of spatiotemporal four-dimensional (4D) positron emission tomography (PET) image reconstruction. The conventional approach to dynamic PET imaging, involving independent reconstruction of individual PET frames, can suffer from limited temporal resolution, high noise (especially when higher frame sampling is introduced to better capture fast dynamics), as well as complex reconstructed image noise distributions that can be very difficult and time consuming to model in kinetic parameter estimation tasks. Various approaches that seek to address some or all of these limitations are described, including techniques that utilize (a) iterative temporal smoothing, (b) advanced temporal basis functions, (c) principal components transformation of the dynamic data, (d) wavelet-based techniques, as well as (e) direct kinetic parameter estimation methods. Future opportunities and challenges with regards to the adoption of 4D and higher dimensional image reconstruction techniques are also outlined.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

4D PET: Beyond conventional dynamic PET imaging

  In this paper, we review novel techniques in the emerging field of spatiotemporal 4D PET imaging. We will discuss existing limitations in conventional dynamic PET imaging which involves independent reconstruction of dynamic PET datasets. Various approaches that seek to attempt some or all of these limitations are reviewed in this work, including techniques that util...

متن کامل

Advances in 4D Gated Cardiac PET Imaging for Image Quality Improvement and Cardiac Motion and Contractility Estimation

Quantitative four-dimensional (4D) image reconstruction methods with respiratory and cardiac motion compensation are an active area of research in ECT imaging, including SPECT and PET. They are the extensions of three-dimensional (3D) statistical image reconstruction methods with iterative algorithms that incorporate accurate models of the imaging process and provide significant improvement in ...

متن کامل

AbstractID: 4788 Title: Model-based statistical image reconstruction for 4D PET

ID: 4788 Title: Model-based statistical image reconstruction for 4D PET Purpose: Four-dimensional (4D) PET can be acquired with gated, dynamic or list mode. In reality, a major problem limiting its clinical application is the poor statistics, since the total coincidence counts in conventional 3D PET are divided into several phase bins and each of them is treated as an independent entity in 4D i...

متن کامل

Four-Dimensional Image Reconstruction Strategies in Cardiac-Gated and Respiratory-Gated PET Imaging.

Cardiac and respiratory movements pose significant challenges to image quality and quantitative accuracy in PET imaging. Cardiac and/or respiratory gating attempt to address this issue, but instead lead to enhanced noise levels. Direct four-dimensional (4D) PET image reconstruction incorporating motion compensation has the potential to minimize noise amplification while removing considerable mo...

متن کامل

3.5D dynamic PET image reconstruction incorporating kinetics-based clusters.

Standard 3D dynamic positron emission tomographic (PET) imaging consists of independent image reconstructions of individual frames followed by application of appropriate kinetic model to the time activity curves at the voxel or region-of-interest (ROI). The emerging field of 4D PET reconstruction, by contrast, seeks to move beyond this scheme and incorporate information from multiple frames wit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medical physics

دوره 36 8  شماره 

صفحات  -

تاریخ انتشار 2009